WATER & POWDER CALIBRATION (Continued)
10. Remove mixing components from dispense head
being tested. Tare catch cup and place under hop-
per elbow of dispense head being tested.
11. Then press and release membrane dispense but-
ton for the dispense head being tested. The unit
will automatically dispense for ten seconds. Run
one cycle but do not use results this primes sys-
tem.
12. Press HOT WATER button, the screen should
change to "Enter Weight X" (where X is head to be
calibrated). Then weigh the catch cup with powder
and enter the weight (in grams). (Use a 5 run av-
erage)

ENTER WEIGHT 1

(-)
54.5 gm
13. Repeat for all stations.
14. Return Program switch to Normal.
15. Two large dispenses are required for auger mo-
(+)
9
tors to adjust if new calibration values have been
entered.