Bunn HWB Installation & Operating Manual page 15

Table of Contents

Advertisement

Exporting to USB
Enter Program mode, go to USB Menu Screen and press yes.
If you press yes in the "EXPORT DRINKCNT?" screen. The drink counts will be exported to the flash drive and placed
on the USB flash drive at "E:\BUNN_USB\IMIXHWB0\DRINKCNT\" and the file will be named DC######.TXT (where
###### is the six digit serial number of the machine the drink counter data was pulled from).
Note the drink counters reset at 50,000. With the exception that the odometer would roll over at 10 digits.
If you press YES in the "EXPORT DRINKHST?" screen. The drink histories will be exported to the flash drive and
placed on the USB flash drive at "E:\BUNN_USB\IMIXHWB0\DRINKHST\" and the file will be named DH######.TXT
(where ###### is the six digit serial number of the machine the drink counter data was pulled from).
Note if the USB board sees more than 1350 drinks without receiving an export drink history command. It will export
the data to a flash drive if one is installed in machine or as soon as one is installed. If no flash drive is found any drinks
over 1350 will start writing over the oldest data. When exporting drink history, fault history will also be exported. The
file will be named FH######.TXT (where ###### is the six digit serial number of the machine the drink counter data was
pulled from). Fault history will overwrite old data if no flash drive is present and over 300 faults have been logged. When
exporting drink counts, drink history and fault history one backup file is created on the USB drive (.bak).
Drink History key:
Drink
1=Head 1
2=Head 2
3=Head 3
4=Head 4
5=Head 5
6=Hot Water
91=Rinse Head 1
92=Rinse Head 2
93=Rinse Head 3
94=Rinse Head 4
95=Rinse Head 5
Size
0=Null
1=Small
2=Medium
3=Large
4=X-large
5=Box
11=Short Small
12=Short Medium
13=Short Large
14=Short X-Large
xx.xx=Rinse Run Time
Fault key:
Fault Element
Event
Number
Number
605
1
605
3
605
72
605
49
1750
0
1751
0
1752
0
1753
0
1754
0
1769
0
1770
0
1771
0
1772
0
1773
0
1774
0
1775
0
1776
0
1777
0
1778
0
1794
0
1796
0
1797
0
1803
0
1804
0
1805
0
1806
0
1807
0
1810
0
1814
0
1831
0
2045
0
2047
0
15
Event
Name
Dispense STOP
All Heads Rinsed
Drink Counters Reset
Factory Defaults Restored
Refill Too Long Fault
Heating Too Long Fault
Overflow Safety Fault
Temperature Sensor Open
Temperature Sensor Short
Powder Hopper 1 Empty
Powder Hopper 2 Empty
Powder Hopper 3 Empty
Powder Hopper 4 Empty
Powder Hopper 5 Empty
Station 1 Locked
Station 2 Locked
Station 3 Locked
Station 4 Locked
Station 5 Locked
Entire Dispenser Locked
Rinse Cycle Cleaning Due
Rinse Cycle Required and Locked
Auger 1 Fault
Auger 2 Fault
Auger 3 Fault
Auger 4 Fault
Auger 5 Fault
Cannot Communicate With The Display Board
Memory Module Locked
Dispense Too Long Fault/Membrane Switch Stuck Fault
Faults Cleared
Machine Powered Up
45398.2 111315