Adjust tank temperature: Range 50-190°F
TANK TEMP XXX°
Default setting leaving factory 190° F
(-)
EXIT
(+)
Adjust minimum tank ready temperature
READY TEMP XXX°
for lockout. 188° maximum setting and
(-)
EXIT
(+)
default setting leaving factory 175°F
Select setting cup size by Time (seconds)
SET CUP SIZE
or by Example
EXMPL
TIME
Press same dispense button to top off cup, or
DISPENSE TO ADD
press save to lock in dispense time, or, press
REPEAT
SAVE
repeat to erase dispense time and repeat process
Adjust hopper motor speed
DRINK STRENGTH
(-)
XX
(+)
for station selected
Calibrate temperature probe
XX° CAL
XX°
(-) Tank Temp (+)
Set refill probe threshold
235 REFILL
155
(-)
EXIT
(+)
Calibrates dilution water flow
CAL WATER ?
rate in station selected
PRESS DISPENSE
Calibrates powder dispense rate
CAL POWDER ?
for hopper in station selected
PRESS DISPENSE
Set delay start of hopper after dilution
Auger Delay
valve opens in station selected
(-)
.XX sec
(+)
Calibrates hopper level sensor in station selected
CAL HOPPER # LPD
Hopper must be at least half full to calibrate
NO
YES
Enables lockout of dispensing when low
LOW POWDER LOCK ?
hopper level is detected
NO
EXIT
YES
Enables lockout of dispensing if below
DISPENSE LOCKOUT
minimum water temperature
NO
EXIT
YES
Allows downloading the drink history data to
EXPORT DRINKHST?
a USB flash drive plugged into the machine
EXIT
YES
Disables all functions and dispensing
HEAD 1 DISABLE ?
for station selected
NO
EXIT
YES
Forces the IMIX main board to try to estab-
ENTER USB MENU ?
lish communications with the USB Board
EXIT
YES
Shows the total number of portion control
STOPPED DISPENSE
dispenses that have been stopped
COUNTS #####
Shows the number of rinse cycles suc-
RINSE COUNTS
cessfully completed for an individual head
SELECT A HEAD
Allows reprogramming the main IMIX
REPRGM IMIXHWB0?
board with a flash drive plugged in
EXIT
YES
Allows reprogramming the USB Board with
REPROGRAM USB ?
a flash drive plugged in
EXIT
YES
Allows downloading the drink counter data to
EXPORT DRINKCNT?
a USB flash drive plugged into the machine
EXIT
YES
Allows password to be set to pre-
SET PASSWORD ?
vent altering setup functions
(-)
XXXX
(+)
GLOSSARY
AUDIBLE ALARM ?
NO
EXIT
DISABLE MESSAGES ?
NO
EXIT
ENABLE ADS ?
NO
EXIT
ENTER ASSET # ?
EXIT
ENABLE SERVICE #
NO
EXIT
TEST SWITCHES ?
Use Switch To Test
TEST HEATER ?
EXIT
TEST REFILL ?
EXIT
TEST HOT WATER ?
EXIT
TEST AUGERS ?
DISPENSE TO TEST
DISPLAY USAGE ?
EXIT
FACTORY DEFAULTS
NO
RINSE ALARM ?
NO
EXIT
VIEW DRINK CNTS?
EXIT
ODOMETER
##########
iMIX VERS ##.##
PRESS FORWARD
USB VERS ##.##
PRESS FORWARD
HOT WATER COUNTS
SELECT A SIZE
SELECT A PORTION
TO VIEW COUNTS
RESET COUNTERS ?
NO
EXIT
HEAD #X RECIPE
RECIPE NAME
IMPORT RECIPES
EXIT
16
Turns on audio alarm
YES
Disables function that displays fault
messages on LCD door display
YES
Enables "ADS" to be displayed
on LCD door display
YES
Enter asset number of machine
YES
Enables service agent telephone
number to be displayed
YES
Allows testing of dispense
switches
Allows manually activating
tank heater
YES
Allows manually activating
refill valve
YES
Allows manually activating hot
water valve
YES
Allows manually activating
hopper motors
Displays amount dispensed
YES
Resets all functions to factory
defaults, and password to 0
YES
Enables rinse alarm
YES
Allows access to the drink counters
YES
Shows the total machine odometer
counter
Alternates between displaying the
software version number of the USB
Board and the IMIX HWB main board
Shows the number of hot water
portion control dispenses
Shows the number of portion size
dispenses for a given size
Allows resetting all the drink counters
(except for the master odometer)
YES
Name of recipe currently on Head X
Import Recipes from USB Drive
YES
45398.2 111315

Advertisement

Table of Contents
loading