Power supply
(cont.)
Outdoor unit power supply 400 V~: Type AWO/
AWO-E/AWO-E-AC 201.A10 to 201.A16
!
Please note
Incorrect phase sequence can cause damage to
the appliance.
Make the compressor power supply only in the
phase sequence specified (see terminals) with a
clockwise rotating field.
GND Rx/Tx- Rx/Tx+
Modbus
C
Fig. 44
Outdoor unit wiring chamber: See page 21.
A
Power supply 400 V/50 Hz
B
Separator (supplied)
C
Danger
Serious injury can be caused by electric current
and appliance damage can result if wires drift
into the adjacent voltage area.
It is essential to insert the separator supplied.
Max. cable length
Vitocal 200-A
Type
400 V appliances
■
■
■
Max. fuse rating
Type AWO/AWO-E/AWO-E-AC
Max. fuse rating
Instantaneous heating water heater power supply
Instantaneous heating water heater:
Type AWO(-M)-E 201.A/AWO(-M)-E-AC 201.A:
■
Factory-fitted
■
Type AWO(-M) 201.A:
Accessories
L1
L2
L3
N
L1
L2
L3
N
B
B
AWO
201.A10
AWO-E
201.A13
AWO-E-AC
201.A16
A
PE
PE
Cable
5 x 2.5 mm
5 x 2.5 mm
5 x 2.5 mm
201.A10
16 A
Installation sequence
Max. cable length
2
2
2
201.A13
201.A16
16 A
30 m
30 m
30 m
16 A
49