Table 3- 1
Description of interfaces
No.
Description
①
Optical PC connection
②
Status LEDs
③
24 V DC supply IN
④
24 V DC supply OUT
⑤
USB connection, Address DIP-switch (PROIFBUS)
and Bus termination switch
⑥
PROFIBUS IN or PROFINET P1
⑦
PROFIBUS OUT or PROFINET P2
⑧
Digital Outputs 0 and 1
3.2
Fitting the CU to the PM
Fitting the Control Unit to the Power Module
The inverter is delivered as two separate components - the Power Module (PM) and the
Control Unit (CU). The CU must be fitted to the PM prior to any further commissioning taking
place.
Seals fitted correctly
It is important that when assembling the Power Module and the Control Unit that all the
seals are fitted correctly to ensure IP65 rating.
TN and TT mains supplies
The SINAMICS PM250D Power Module with the Class A integrated mains filter is only
suitable for operation on TN and TT mains supplies.
The CU is fitted to the PM as shown in the diagram below.
Getting Started
Getting Started, FW V4.5, A5E03404762A AB
CAUTION
No.
Description
⑨
HTL Encoder connection
⑩
Digital Inputs 0 and 1
⑪
Digital Inputs 2 and 3
⑫
Digital Inputs 4 and 5
⑬
SSI Encoder or Analog Inputs 0 and 1 (depending on
type of CU)
⑭
PE grounding terminal
⑮
Mains supply connection
⑯
Motor, brake and temperature sensor connections
Installation
3.2 Fitting the CU to the PM
15