Setting The Alarm Output - Alarm Output Menu; Alarm Out 1, 2 Tab - Sony SNC-RX530N User Manual

Ipela dynaview network camera
Hide thumbs Also See for SNC-RX530N:
Table of Contents

Advertisement

Setting the Alarm Output
— Alarm output Menu
When you click
the Alarm output menu appears.
You can perform setting in this menu to control the
alarm output of the I/O port on the rear of the camera
linked to the alarm detection, the timer and the Day/
Night function.
The Alarm output menu consists of two tabs: Alarm
out 1 and Alarm out 2.
Tip
For the connection of peripheral devices to the alarm
output of the I/O port, see the supplied Installation
Manual.

Alarm out 1, 2 Tab

Alarm output
To activate the alarm output function, select On.
Mode
Select the mode of the alarm output function.
Alarm: Controls alarm output by synchronizing it with
an external sensor input or the built-in object
detection function.
When Alarm is selected, the items Sensor input 1,
Sensor input 2, Object detection, Alarm duration
and Effective period become active.
Timer: Controls alarm output using the timer.
Click Schedule and the menu for the effective period
is displayed. ("Setting the Schedule — Schedule
Menu" on page 75)
Day/Night: Controls the alarm output linked to the day/
night function.
in the Administrator menu,
Sensor input 1
Select this option when you link the alarm output to an
external sensor that is connected to sensor input 1 of the
camera I/O port.
Sensor input 2
Select this option when you link the alarm output to an
external sensor that is connected to sensor input 2 of the
camera I/O port.
Object detection
Select this option when you link the alarm output to the
object detection function.
Click Detection, and the Object detection menu is
displayed to allow you to set the object detection
function (page 77).
Note
In the case that the synchronized preset position is
specified in Position at alarm in the Preset position
menu, the alarm event that happens when the camera
moves to the preset position will be invalid.
Alarm duration
Select the duration for which the alarm output is short-
circuited between 1 and 60 sec.
Effective period
This item becomes active when Mode is set to Alarm.
Set the period during which the alarm detection is
effective.
Always: The alarm detection is always effective.
Schedule: You can specify the period during which
alarm detection is effective.
Click Schedule and the menu for the effective period
is displayed. ("Setting the Schedule — Schedule
Menu" on page 75)
OK/Cancel
See "Buttons common to every menu" on page 30.
Setting the Alarm Output — Alarm output Menu