Sequence number clear
Click Clear to reset the Sequence number suffix to 1.
Alarm
Select the alarm to be linked with the recording of image
and audio files.
Sensor input 1: The external sensor that is connected to
sensor input 1 of the camera I/O port.
Sensor input 2: The external sensor that is connected to
sensor input 2 of the camera I/O port.
Object detection: The alarm by the object detection
function.
Click Detection, and the Object detection menu is
displayed to allow you to set the object detection
function (page 77).
Note
In the case that the synchronized preset position is
specified in Position at alarm in the Preset position
menu, the alarm event that happens when the camera
moves to the preset position will be invalid.
Effective period
Set the period during which alarm detection is effective.
Always: The alarm detection is always effective.
Schedule: You can specify the period during which
alarm detection is effective.
Click Schedule and the setting menu for the effective
period is displayed. ("Setting the Schedule —
Schedule Menu" on page 75)
Alarm buffer
Select Use alarm buffer when you record the image/
audio of before and after alarm detection (pre-alarm,
post-alarm).
If you do not select the alarm buffer, only the image at
the moment of the alarm detection is recorded.
Click Alarm buffer to display the Alarm buffer menu.
For details, see "Setting the Alarm Buffer — Alarm
buffer Menu" on page 76.
Note
This setting becomes invalid and a still image is
recorded if H.264 is selected in the Video codec tab of
the Camera menu.
OK/Cancel
See "Buttons common to every menu" on page 30.
68
Recording Images in Memory — Image memory Menu
Periodical recording Tab — Setting
the periodical recording mode
You can set to record the image file (JPEG file) in the
built-in memory, ATA memory card or "Memory Stick"
periodically.
Periodical recording
Select On when you want to use periodical recording.
Image file name
Type the file name of the image to be recorded to the
memory using up to 10 alphanumeric characters, -
(hyphen) and _ (under score).
The actual image file name will be the specified image
file name with the a suffix and the extension .jpg.
Note
You cannot record the audio file using the periodical
recording function.
Suffix
Select a suffix to be added to the file name.
None: The recording file name will be the image file
name.
Date & time: The date & time suffix is added to the
image file name.
The date/time suffix consists of lower two-digits of
the year (2 digits), month (2 digits), date (2 digits),
hour (2 digits), minute (2 digits), second (2 digits),
and consecutive number (2 digits), thus adding a 14-
digit number to the image file name.
Sequence number: A consecutive number of 10 digits
between 0000000001 and 4294967295 and two fixed
digits 00 are added to the image file name.
Sequence number clear
Click Clear to reset the Sequence number suffix to 1.