Mitsubishi SRK20ZSX-W Technical Manual page 51

Inverter wall mounted type residential air-conditioners (split system, air to air heat pump type)
Table of Contents

Advertisement

(2) Correction of cooling and heating capacity in relation to one way length of refrigerant piping
Piping length [m]
Cooling
Heating
(3) Correction relative to frosting on outdoor heat exchanger during heating
Air inlet temperature of
outdoor unit in °C WB
Adjustment coefficient
How to obtain the cooling and heating capacity
7
10
15
1.0
0.99
0.975
1.0
1.0
1.0
-20
-15
-10
0.95
0.95
0.95
W
W
49
-
20
25
0.965
0.95
1.0
1.0
-9
-7
-5
-3
0.94
0.93
0.91
0.88
=
-
'09•SRK-DB-087D
'18 • SRK-T-234
30
0.935
1.0
-1
1
3
0.86
0.87
0.92
5 or more
1.00

Hide quick links: