Mitsubishi SRK20ZSX-W Technical Manual page 124

Inverter wall mounted type residential air-conditioners (split system, air to air heat pump type)
Table of Contents

Advertisement

(c) Operation and setting from wired remote control
Setting & display item
1.Remote control network
1 Control plural indoor units by a single remote control
2 Main/sub setting of remote controls
2.TOP scrren, Switch manipulation
1 Menu
2 Operation mode
3 Set temp.
4 Air flow direction
5 Fan speed
6 Timer setting
7 ON/OFF
8 F1 SW
9 F2 SW
3.Useful functions
1 Individual flap control
2 Anti draft setting
When the panel with the anti-draft function is assembled.
3 Timer settings
Set On timer by hour
Set Off timer by hour
Set On timer by clock
Set Off timer by clock
Confirmation of timer settings Status of timer settings can be seen.
4 Favorite setting
[Administrator password]
5 Weekly timer
6 Home leave mode
[Administrator password]
7 External Ventilation
When the ventilator is combined.
8 Select the language
9 Look, look
10 Power consumption indication
4.Energy-saving setting
1 Sleep timer
2 Peak-cut timer
3 Automatic temp. set back
4 Infrared sensor control (Motion sensor control)
When the panel with the infrared sensor (motion sensor) is
assembled.
5.Filter
Filter sign reset
1 Filter sign reset
Setting next cleaning date
6.User setting
Clock setting
1 Internal settings
Date and time display
Summer time
Contrast
Backlight
Control sound
Operation lamp luminance
A remote control can control plural indoor units up to 16 (in one group of remote control network).
An address is set to each indoor unit.
A pair of remote controls (including optional wireless remote control) can be connected within the remote control
network. Set one to "Main" and the other to "Sub".
"Control","State", or "Details" can be selected. (3-8)
"Cooling","Heating","Fan","Dry" or "Auto" can be set.
"Set temperature" can be set by 0.5˚C interval.
"Air flow direction" [Individual flap control] can be set.
Select Enable or Disable for the "3D AUTO" .
"Fan speed" can be set.
"Timer operation" can be set.
"On/Off operation of the system" can be done.
The system operates and is controlled according to the function specified to the F1 switch.
The system operates and is controlled according to the function specified to the F2 switch.
The moving range (the positions of upper limit and lower limit) of the flap for individual flap can be set.
When the panel with the anti draft function is assembled, select to Enable or Disable the anti draft setting for each
operation mode and for each blow outlet.
The period of time to start operation after stopping can be set.
・The period of set time can be set within range of 1hour-12houres (1hr interval).
・The operation mode, set temp. and fan speed at starting operation can be set.
The period of time to stop operation after starting can be set.
・The period of set time can be set within range of 1hour-12houres (1hr interval).
The clock time to start operation can be set.
・The set clock time can be set by 5 minutes interval.
・[Once (one time only)] or [Everyday] operation can be switched.
・The operation mode, set temp and fan speed at starting operation can be set.
The clock time to stop operation can be set.
・The set clock time can be set by 5 minutes interval.
・[Once (one time only)] or [Everyday] operation can be switched.
Set the operation mode, setting temperature, air flow capacity and air flow direction for the choice setting operations.
Set them for the Favorite set 1 and the Favorite set 2 respectively.
On timer and Off timer on weekly basis can be set.
・8-operation patterns per day can be set at a maximum.
・The setting clock time can be set by 5 minutes interval.
・Holiday setting is available.
・The operation mode, set temp and fan speed at starting operation can be set.
When leaving home for a long period like a vaction leave, the unit can be operated to maintain the room temperature
not to be hotter in summer or not to be colder in winter.
・ The judgment to switch the operation mode (Cooling ⇔Heating) is done by the both factors of the set temp. and outdoor
air temp.
・The set temp. and fan speed can be set.
On/Off operation of the external ventilator can be done.
It is necessary to set from [Menu] ⇒ [Service setting] ⇒ [R/C function settings] ⇒ [Ventilation setting].
・ If the "Independent" is selected for the ventilation setting, the ventilator can be operated or stopped.
Select the language to display on the remote control.
・Select from English, German, French, Spanish, Italian, Dutch, Turkish, Portuguese, Russian,
Polish, Japanese and Chinese.
Indoor temperature, outdoor temperature and power consumption are indicated.
The power consumption of today, this week and this year is indicated by a chart. It is possible to compare with
yesterday, last week and last year.
・This item may not indicate depending on indoor and outdoor units which are combined.
Administrator password
To prevent the timer from keeping ON, set hours to stop operation automatically with this timer.
・The selectable range of setting time is from 30 to 240 minutes. (10 miuutes interval)
・When setting is "Enable", this timer will activate whenever the ON timer is set.
Power consumption can be reduced by restructing the maximum capacity.
Set the [Start time], the [End time] and the capacity limit % (Peak-cut %).
・4-operation patterns per day can be set at maximum.
・The setting time can be changed by 5-minutes interval.
・The selectable range of capacity limit % (Peak-cut % ) is from 0% to 40-80% (20% interval).
・Holiday setting is available.
After the elapse of the set time period, the current set temp. will be set back to the [Set back time.]
・The setting can be done in cooling and heating mode respectively.
・Selectable range of the set time is from 20 min. to 120 min. (10 min. interval).
・Set the [Set back temp.] by 1˚C interval.
When the infrared sensor (motion sensor) is used, it is necessary to set Enable or Disable for the "Power control"
and the "Auto-off".
The filter sign can be reset.
The next cleaning date can be set.
The current date and time can be set or revised.
・If a power failure continues no longer than 80 hours, the clock continues to tick by the built-in power source.
[Display] or [Hide] the date and/or time can be set, and [12H] or [24H] display can be set.
When select [Enable], the +1hour adjustment of current time can be set. When select [Disable], the [Summer time]
adjustment can be reset.
The contrast of LCD can be adjusted higher or lower.
Switching on/off a light can be set and period of the lighting time can be set within the range of 5sec-90 sec (5sec interval).
It can set with or without [Control sound (beep sound)] at touch panel.
This is used to adjust the luminance of operation lamp.
122
-
-
Blank:Not compatible
−:No function on remote control
○:Correspondence