2.0

Quick Reference Terminal Description

Terminal
Name
1, 2
CLASS 2
TRANSFORMER
3
+ AUX POWER
4
BATTERY
NEGATIVE ONLY
5 (+)
BATTERY
POSITIVE ONLY
6 (+)
+ STEADY OR
PULSED ALARM
POWER
7 (+)
+ ALTERNATE
ALARM POWER
8 (+)
+ SWITCHED
AUX POWER
9
COMMON
10
EARTH GROUND
11, 13, 14,
ON-BOARD
16, 17, 19,
POINTS
20, 22
(Inputs)
12, 15, 18,
ON-BOARD
21
POINTS
(Common)
23 (-)
ZONEX
COMMON
24 (+)
ZONEX POWER +
25
ZONEX IN 2
26
ZONEX OUT 2
27
ZONEX IN 1
28
ZONEX OUT 1
29 (-)
COMMON
30
DATA BUS B
31
DATA BUS A
32 (+)
POWER +
D9412G/D7412G/D7212G Installation & Troubleshooting Quick Reference Guide
© 2004 Bosch Security Systems, Inc.
Quick Reference Terminal Description
Connect 16.5 VAC, 40 VA transformer for primary power supply.
Supplies up to 1.4 A at 10.2 VDC to 13.9 VDC to powered devices. Use Terminal
9 for common. Shares PTC with Terminal 24.
Connect rechargeable lead acid type battery's negative terminal (-) to Terminal
4. (See the Current Rating Charts section in the panel's Approved Applications
Compliance Guide to determine battery size requirements.)
Connect rechargeable lead acid type battery's positive terminal (+). (See the
Current Rating Charts section in the panel's Approved Applications Compliance
Guide to determine battery size requirements.)
Supplies up to 2 A at 10.2 VDC to 13.9 VDC for steady or pulsed alarm output.
Use Terminal 9 for common. Programmed as Relay A. Shares PTC with
Terminals 7 and 8.
Supplies up to 2 A at 10.2 VDC to 13.9 VDC for steady or pulsed alarm output.
Use Terminal 9 for common. Programmed as Relay B. Shares PTC with
Terminals 6 and 8.
D136 Plug-in Relay required: Install a D136 in the ALT ALARM socket for
output at Terminal 7.
Supplies up to 1.4 A at 10.2 VDC to 13.9 VDC. Use Terminal 9 for common.
Programmed as Relay C. Continuous output interrupted by RESET SENSORS
or alarm verification. Shares PTC with Terminals 6 and 7.
D136 Plug-in Relay required: Install a D136 in the SW AUX socket for output at
Terminal 8.
Terminal 9 is common for Auxiliary Power, Steady or Pulsed Alarm Power,
Alternate Alarm Power, and Switched Aux Power (Terminals 3, 6, 7, and 8).
Connect to earth ground. A cold water pipe or grounding rod is preferred.
Do not connect to telephone or electrical ground.
Connect normally open and/or normally closed detection devices to loop wiring.
1 kΩ resistor required at end of loop.
Loop returns for on-board points.
[D9412G only] Use Terminals 23 and 24 to power ZONEX modules such as
the
D8125 POPEX module, the D8128D OctoPOPIT, and the D8129 OctoRelay.
Shares PTC with Terminal 3.
[D9412G only] Connect ZONEX modules for Points 129 to 247 and Relays
65 to 128 to these terminals.
Connect ZONEX modules for Points 9 to 127 and Relays 1 to 64 to these
terminals. (The D7412G uses Points 9 to 75, the D7212G uses Points 9 to 40.)
Common terminal for SDI devices.
Terminals 30 and 31 are a two-wire bus that drives the command centers,
printer interface, and access control modules including the D9133TTL-E
Ethernet Interface Module, D9133DC Direct Connect Module, D9133 Serial
Interface Module, and the PC9133TTL-E Ethernet Interface Module.
Power for SDI devices. Shorts on any other terminal do not affect this separate,
protected power output for SDI devices.

Table 3: Quick Reference Terminal Description

Page 7
D9412G/D7412G/D7212G
Description
43700F