Dynamic Convergence Adjustment - Sony TRINITRON KV-29FX11A Service Manual

Sony crt television user manual
Hide thumbs Also See for TRINITRON KV-29FX11A:
Table of Contents

Advertisement

KV-29FX11
Operation of the BMC (Hexapole) magnet.
R G
B
R
R
B
R
G
The respective dot position resulting from moving each
magnet interact, so be sure to perform adjustment whilst
tracking.
Use the H.STAT VR to adjust the Red, Green and Blue dots
so that they coincide at the centre of the screen
(by moving the dots in the horizontal direction).
(2)

Dynamic convergence adjustment.

Preparation:
Before starting this adjustment, adjust the horizontal and
vertical static convergence.
1.
Remove the deflection yolk spacer.
R
G
R
G
B
G
R
G
B
R
G B
G
B
G
R
B
B
B
R
G
B
V.STAT
2.
Tilt the deflection yolk as indicated in the figure below and
optimize the convergence.
3.
Re-install the deflection yolk spacer.
Note :
This adjustment will affect the geometry of the
display, therefore adjust to obtain the optimum
setting.
Tilt Direction
26
Purity
BMC (Hexapole)
R
B
G
G
B
R
R
G
B
R
G
B

Hide quick links:

Advertisement