Be-3D Self Diagnostic Software; Flash Timing Example - Sony TRINITRON KV-29FX11A Service Manual

Sony crt television user manual
Hide thumbs Also See for TRINITRON KV-29FX11A:
Table of Contents

Advertisement

4-3. BE-3D SELF DIAGNOSTIC SOFTWARE

The identification of errors within the BE-3D chassis is triggered in one of two ways :- 1: Busy busy or 2: Device failure to respond to IIC. In the
event of one of these situations arising the software will first try to release the bus if busy [Failure to do so will report with continuous flashing
LED] and then communicate with each device in turn to establish if a device is faulty. If a device is found to be faulty the relevant device number
will be displayed through the LED [Series of flashes which must be counted] See Table 1., non fatal errors are reported using this method.
ERROR
No error
Not allowed (may be confused with Sircs response
flash!)
Protection circuit trip < ANY TIME >
IIC SCL LOW < POWER UP ONLY >
IIC SDA LOW < POWER UP ONLY >
IIC SDA & SCL LOW < POWER UP ONLY >
Jungle / Chroma controller no acknowledge
< POWER UP ONLY >
Video Switch no acknowledge
< POWER UP ONLY >
Tuner no acknowledge
MSP no acknowledge
NVM no acknowledge
M3L TXD Low < POWER UP ONLY >
M3L RXD Low < POWER UP ONLY >
M3L ENABLE Low < POWER UP ONLY >
M3L TXD & RXD Low < POWER UP ONLY >
Compact Text test fail < POWER UP ONLY >
AV switch cannot power on reset
< Chassis Initialisation >
Cannot initialise jungle ( after initial power on
checked out OK ) - < Chassis initialisation >
NVM acknowledge fail after initialisation (STBY +5V
same as micro!)
Multiple devices with no acknowledge
< POWER UP ONLY >
Compact text run-time failure after power up check
(+9V test)
AV SWITCH response failure after power up check
(+9V test)
JUNGLE / CHROMA controller response failure
after power up check (-9V test)
Compact text does not respond (-5V test)
MSP run-time failure
< MAY NOT BE FATAL-DISPLAY ON ERROR
READER >
LED
ERROR
COUNT
00
M3L bus Clock low time out after data send
( run-time failure)
01
M3L bus Clock low time out after data send
( at power up check )
02
M3L bus Clock low time out after data send
03
( at initialisation )
04
DSP run-time failure
05
< MAY NOT BE FATAL-DISPLAY ON ERROR
READER >
06
Flash Timing Example : e.g. error number 3
07
08
StBy LED
09
ON
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
33
ON
OFF
OFF
KV-29FX11
25
26
27
28
ON