5-2. CONVERGENCE ADJUSTMENT

Preparation:
• Before starting, perform FOCUS adjustment.
• Receive dot/cross hatch pattern.
• Picture Mode "CUSTOM" (PIC 90%, BRT 50%,
COL 50%, HUE 50%, SHP 50%).
a) Vertical Static Convergence
Center dot
R
G
B
R
G
B
1. (Moving vertically), adjust the 4 pole magnet to converge
red, green and blue dots in the center of
the screen.
2. Tilt the 4 pole magnet and adjust static convergence
to open or close the 4 pole magnet.
3. When the 4 pole magnet is moved in the direction of
arrow A and B, the red, green and blue dots moves
as shown below:-
A
B
B
Moved RV9001 (H.STAT)
R
G
B
4 pole
magnet
Y magnet
RV9001
4-pole
C Board
a
b
B
B
G
G
R
R
R
G
B
b) Horizontal Static Convergence
If the blue dots does not converge with the red and
green dots, use the 6 pole magnet to adjust in
the manner described below:-
R G
B
R
B
G
DY pocket
4 Pole
Magnet
c) Y Separation axis correction magnet adjustment.
1. Receive cross hatch signal.
2. Set Picture to "MINIMUM", Brightness to
"STANDARD".
3. Adjust the Y separation axis correction magnet on
the Neck Assembly so that the horizontal lines at
the top and bottom of the screen are straight.
Blue
Red
Neck assy
Red
VM1 Board
– 11 –
KV-DA322M64/M66
R
G
B
R
G B
R
G
B
G
R
B
6 Pole
Magnet
6 Pole Magnet
Purity
4 Pole Magnet
Red
Neck assy
Blue
VM1 Board
RM-GA001
Blue