Wiring Diagrams; Indoor Unit; Outdoor Unit - Daikin Urusara 7 FTXZ-N Series Engineering Data

Split type air conditioners - heat pump
Table of Contents

Advertisement

EDMY041425

5. Wiring Diagrams

5.1

Indoor Unit

FTXZ25/35/50NVMM
FIELD WIRING.
indoor
GRN/YLW
GRN/YLW
FG1
8
5.2

Outdoor Unit

RXZ25/35/50NVM
INDOOR
1
2
3
L
N
NOTE
1. REFER TO THE NAME PLATE FOR THE POWER
REQUIREMENTS.
.DB1, DB3
: DIODE BRIDGE
.FU1, FU2, FU3
: FUSE
.HK1, HK2, HK3
: CONNECTOR
.IPM1, IPM2
: INTELLIGENT POWER MODULE
.L
: LIVE
.L1R, L2R
: REACTOR
.MRK, MR4, MR30
: MAGNETIC RELAY
.MRM10, MRM20
: MAGNETIC RELAY
.M1C
: COMPRESSOR MOTOR
.M1F
: FAN MOTOR
Split Type Air Conditioners FTXZ-N Series
M1S
M2S
outdoor
MSW
MSW
1
2
3
A4P
R2T
HUMIDITY
SENSOR
1
4
X1M
1
2 3
4
E1
(H250V,T3.15A) H1
1
4
C105
H3
R1V
F1U
S33
C104
U
H2
+
MR10
_
_
TRANSMISSION
CIRCUIT
_
+
IPM200
S32
7
4
1
2
1
1
S200
R1T
A2P
1
S1W
MS
SIGNAL
3~
TRANSMITTER
SIGNAL
LED2 LED4
M1F
WIRELESS
RECEIVER
REMOTE
H2P H4P
CONTROLLER
FIELD WIRING
1
YLW
S45
102˚C
3
YLW
Z1C
FU3
N=6
30A
HL1
L
1
BLK
HN1
N
2
V5
WHT
S
U
3
RED
GRN/
E1
GRY
V3
YEL
Z2C
X1M
U
N=3
E2
GRN
HK3
HK2
HK1
1
S101
4
1
2
3
S21
7
1
S22
5
1 S501
OUTDOOR
2
.N
.PCB1
.Q1M
.R1T, R2T, R3T
.R5T
.SA1
.V3, V5
.X5A, X6A
.X1M
.Y1E
M3S
M4S
M5S
MSW
MSW
MSW
M6S
M7S
M8S
MSW
MSW
MSW
29
5
5
5
1
20
1
S44
A1P
S46
15
AREA B(L)
BLK
1
15
A6P
BLK
3
BLK
15
INTELLIGENT
S56
EYE SENSOR
F1UT
6
AREA A ( R )
S26
1
BLK
136˚C
A7P
BLK
LED5 LED1
3
1
BLK
INTELLIGENT
H5PH1P
EYE SENSOR
L1R
MRM20
DB1
+
HR1
HR2
MRM10
HR3
FU1
PCB1
MR30
3.15A
SA1
DB3
+
MRK
MR4
S91
S20
S90
S80
S72
1
2
1
6
1
6
1
3
2
3
4
5
M
Y1S
Y1E
R5T
R1T
R2T
R3T
(OUTDOOR)
(DISCHARGE)
(CONDENSER)
: NEUTRAL
.Y1S
: PRINTED CIRCUIT BOARD
.Z1C, Z2C, Z3C, Z4C
: OVERLOAD PROTECTOR
: THERMISTOR
: LIQUID PIPE THERMISTOR
: SURGE ARRESTER
: VARISTOR
: CONNECTOR
: TERMINAL STRIP
: ELECTRONIC EXPANSION VALVE COIL
CAUTION
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.
A1P~A4P
A6P, A7P
: PRINTED CIRCUIT BOARD
C104, C105
: CAPACITOR
FG1
: FLAME GROUND
F1U
: FUSE
F1UT
: THERMAL FUSE
H1P, H2P
H4P, H5P
: PILOT LAMP
S1C
: LIMIT SWITCH FOR BRUSH
: LIMIT SWITCH FOR STREAMER
S2C
M1F
: FAN MOTOR
M1S~M8S
: SWING MOTOR
MR10
: MAGNETIC RELAY
R1T, R2T
: THERMISTOR
R1V
: VARISTOR
S16~S401
CN403, B401
: CONNECTOR
S1W
: OPERATION SWITCH
X1M
: TERMINAL STRIP
: PROTECTIVE EARTH
30
S41
1
S16
4
1
S21
HA 5
S53
S52
1
5
3
1
5
CN403
1
6
S401
WHT
HIGH VOLTAGE
WHT
UNIT
B401
STREAMER
A3P
PART
L2R
Z4C
N=3
IPM1
+
+
HR4
FU2
3.15A
IPM2
+
S70
S40
8
1
4
7
1
2
U
V W
Z3C
N=3
X6A
X5A
V
MS
MS
~
3
U
W
M1F
Q1M
M1C
: REVERSING SOLENOID VALVE COIL
: FERRITE CORE
.
: PROTECTIVE EARTH
Wiring Diagrams
3D086394
3D086397B
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ftxz25nvmmRxz35nvmFtxz35nvmmRxz50nvmFtxz50nvmmRxz25nvm

Table of Contents