Dimensions; Indoor Unit; Outdoor Unit - Daikin Urusara 7 FTXZ-N Series Engineering Data

Split type air conditioners - heat pump
Table of Contents

Advertisement

Dimensions

4. Dimensions
4.1

Indoor Unit

FTXZ25/35/50NVMM
798
LEFT GRILLE FIXED SCREWS
OPERATION LAMP
(INSIDE PANEL)
INTELLIGENT EYE
SENSOR
TIMER LAMP
AUXILIARY FLAP
(HORIZONTAL BLADE)
FLAP
(HORIZONTAL BLADE)
TRANSMITTER / RECEIVER
56
30
CIRCULATION
FLOW
AIR CLEANING
UPPER LIMIT
(SINGULARITY OPERATION)
COOLING UPPER LIMIT
DEHUMIDIFICATION
UPPER LIMIT
DEHUMIDIFICATION COOLING
UPPER LIMIT
HEATING UPPER LIMIT
WIRELESS REMOTE
CONTROLLER
(ARC477A2)
4.2

Outdoor Unit

RXZ25/35/50NVM
18
OUTDOOR AIR THERMISTOR
20
MINIMUM SPACE FOR AIR PASSAGE WALL HEIGHT ON AIR OUTLET SIDE
50
6
THE MARK (→) SHOWS PIPING DIRECTION
QUICK HEATING
TIMER LAMP
MOLD PROOF
CLEANING FILTER LAMP
TRANSMITTER / RECEIVER
OPERATION ON/OFF SWITCH
(INSIDE PANEL)
RIGHT GRILLE FIXED
SCREWS
(INSIDE PANEL)
TERMINAL BLOCK
WITH EARTH TERMINAL
(AFTER REMOVING THE
SERVICE COVER)
MODEL NAME PLATE
BLADE ANGLE
AUXILIARY FLAP
CIRCULATION
FLOW
13˚
AIR CLEANING
55˚ 65˚
UPPER LIMIT
(SINGULARITY OPERATION)
COOLING UPPER LIMIT
AIR CLEANING
DEHUMIDIFICATION
LOWER LIMIT
UPPER LIMIT
DEHUMIDIFICATION
(SINGULARITY OPERATION)
COOLING UPPER LIMIT
HEATING LOWER LIMIT
HEATING UPPER LIMIT
COOLING LOWER LIMIT
DEHUMIDIFICATION LOWER LIMIT
DEHUMIDIFICATION COOLING LOWER LIMIT
DRAIN OUTLET
(I.D. φ15.9
HOSE FOR CONNECTION)
15
17
300
20
HANDLE
= LESS THAN 1200
50
50
REQUIRED SPACE
DISTANCE FROM WALL
MIN.50 FOR OPERATION
(RECOMMENDED)
372
MIN.20 FOR INSTALLATION
370
NAME PLATE
SECURE THE CLEARANCE 15mm
FROM INDOOR UNIT WHEN (∗) IS
OVER 70mm BY CURTAIN RAIL
(∗)
SHUTTER
(BOTTOM AIR INLET)
150
179
328
MAIN FLAP
13˚
17˚
28˚
55˚ 65˚
AIR CLEANING
LOWER LIMIT
(SINGULARITY OPERATION)
HEATING LOWER LIMIT
COOLING LOWER LIMIT
DEHUMIDIFICATION LOWER LIMIT
DEHUMIDIFICATION COOLING LOWER LIMIT
574
90.5
495
4-HOLES FOR ANCHOR BOLTS
(M8 OR M10)
795
63
328.5
BRAND NAME LABEL
MANUFACTURER'S LABEL
326
(BASE PITCH)
342
Split Type Air Conditioners FTXZ-N Series
AIR FLOW (INDOOR)
DISTANCE FROM WALL
MIN.50 FOR OPERATION
(RECOMMENDED)
MIN.20 FOR INSTALLATION
APPROX. 350
GAS PIPE 9.5CuT
APPROX. 400
LIQUID PIPE 6.4CuT
DRAIN HOSE CONNECTING PART
APPROX. 430
LIQUID PIPE
GAS PIPE
APPROX. 330
APPROX. 380
APPROX. 400
798
645
72
48
48
WALL HOLE FOR EMBEDDED PIPING φ65 HOLE
STANDARD LOCATIONS OF WALL HOLES
TERMINAL STRIP
WITH EARTH TERMINAL
LIQUID
STOP VALVE
(φ6.4 CuT)
GAS
STOP VALVE
(φ9.5 CuT)
SERVICE
PORT
13
156
IN CASE OF REMOVING
STOP VALVE COVER
EDMY041425
DRAIN HOSE
3D086877
3D086876