Capacity Tables
FTXZ35NVMM + RXZ35NVM (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
Cooling
AFR
12.1
BF
0.14
INDOOR
EWB EDB
–10
°C
°C
TC
SHC
14.0
20
4.50
3.27
0.27
16.0
22
4.66
3.19
0.27
18.0
25
4.82
3.31
0.33
19.0
27
4.90
3.48
0.33
22.0
30
5.13
3.33
0.38
24.0
32
5.29
3.23
0.39
INDOOR
EWB EDB
20
°C
°C
TC
SHC
14.0
20
3.53
2.79
0.52
16.0
22
3.69
2.74
0.52
18.0
25
3.85
2.90
0.53
19.0
27
3.93
3.08
0.53
22.0
30
4.17
2.98
0.53
24.0
32
4.33
2.91
0.54
Heating
AFR
13.3
INDOOR
EDB
–15
°C
TC
PI
15.0
2.38
0.64
2.86
20.0
2.23
0.66
2.71
22.0
2.18
0.67
2.66
24.0
2.12
0.68
2.60
25.0
2.09
0.68
2.57
27.0
2.03
0.69
2.51
Symbols:
AFR
: Airflow rate
BF
: Bypass factor
EWB
: Entering wet bulb temp.
EDB
: Entering dry bulb temp.
TC
: Total capacity
SHC
: Sensible heat capacity
PI
: Power input
10
OUTDOOR TEMPERATURE (°CDB)
–5
PI
TC
SHC
PI
TC
4.34
3.19
0.27
4.18
4.50
3.11
0.27
4.34
4.66
3.24
0.33
4.50
4.74
3.41
0.33
4.57
4.97
3.27
0.38
4.81
5.13
3.17
0.39
4.97
OUTDOOR TEMPERATURE (°CDB)
25
PI
TC
SHC
PI
TC
3.37
2.71
0.57
3.21
3.53
2.67
0.57
3.37
3.69
2.83
0.58
3.53
3.77
3.01
0.58
3.61
4.01
2.92
0.58
3.85
4.17
2.85
0.59
4.01
OUTDOOR TEMPERATURE (°CWB)
–10
–5
TC
PI
TC
PI
TC
0.68
3.34
0.71
4.50
0.69
3.19
0.73
4.32
0.70
3.14
0.73
4.25
0.71
3.08
0.74
4.18
0.71
3.05
0.75
4.15
0.72
2.99
0.75
4.08
(m³/min.)
(°C)
(°C)
(kW)
(kW)
(kW)
0
5
SHC
PI
TC
SHC
3.11
0.32
4.02
3.03
3.04
0.32
4.18
2.96
3.17
0.33
4.33
3.10
3.34
0.33
4.41
3.28
3.21
0.38
4.65
3.15
3.12
0.39
4.81
3.06
30
35
SHC
PI
TC
SHC
2.64
0.62
3.05
2.56
2.60
0.63
3.21
2.53
2.76
0.63
3.37
2.70
2.95
0.63
3.45
2.89
2.86
0.63
3.69
2.81
2.80
0.64
3.85
2.75
0
6
10
PI
TC
PI
TC
0.93
5.17
0.98
5.62
0.95
5.00
1.00
5.45
0.96
4.93
1.01
5.38
0.97
4.86
1.02
5.31
0.97
4.83
1.02
5.28
0.98
4.76
1.03
4.83
Notes:
1. Ratings shown are net capacities which include a deduction for indoor fan
motor heat.
2.
shows nominal (rated) capacities and power input.
3. TC, PI and SHC must be calculated by interpolation using the figures in the
above tables. (Figures out of the tables should not be used for calculation.)
4. About SHC which are not mentioned in the table, please calculate them with
around values in direct proportion.
5. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 7.5 m
Level difference : 0 m
6. Airflow rate (AFR) and Bypass factor (BF) are tabulated in the above table.
10
PI
TC
SHC
PI
TC
0.37
3.86
2.95
0.42
3.70
0.37
4.01
2.89
0.42
3.85
0.38
4.17
3.03
0.43
4.01
0.38
4.25
3.21
0.43
4.09
0.38
4.49
3.09
0.43
4.33
0.39
4.65
3.01
0.44
4.49
40
PI
TC
SHC
PI
0.67
2.89
2.49
0.68
0.68
3.05
2.46
0.68
0.68
3.21
2.63
0.69
0.68
3.29
2.82
0.69
0.68
3.53
2.75
0.69
0.69
3.69
2.70
0.69
PI
1.01
1.03
1.04
1.05
1.05
0.96
Split Type Air Conditioners FTXZ-N Series
EDMY041425
15
SHC
PI
2.87
0.45
2.81
0.47
2.96
0.48
3.14
0.48
3.03
0.48
2.96
0.49
3D087022A