Outdoor Installations; Ambient Conditions And Air Circulation - Delta RPI M50A_120 Installation And Operation Manual

Table of Contents

Advertisement

5.2

Outdoor installations

Fig. 5.4:
Outdoor installations
► The solar inverter has protection degree IP65 and
can be installed indoors or in protected outdoor
areas (that means outdoor but protected by a roof
against direct sun, rain or snow).
Installation and Operation Manual for RPI M50A
5.3
► Ensure adequate air circulation. Hot air must be
► Do not install inverters directly above one another.
► Consider the operating temperature range (see
Fig. 5.21: Air fl ow around solar inverter
5 Planning the installation
Ambient conditions and air circula-
tion
>30 cm
>30 cm
Fig. 5.5:
Mounting distances and air circulation
able to dissipate downward. Keep enough space
around each inverter.
Otherwise, the lower inverter is warmed up by the
upper one.
"13. Technical data", p.
When the operating temperature range is exceed-
ed, the solar inverter reduces the amount of power
generated.
>30 cm
105).