Fisher & Paykel HD30 Installation Instructions Manual
Fisher & Paykel HD30 Installation Instructions Manual

Fisher & Paykel HD30 Installation Instructions Manual

Hide thumbs Also See for HD30:

Advertisement

Quick Links

Installation Instructions
Downdraft Unit Contents of Packaging
End cap (2)
Installation instructions
10" (254 mm) remote blower
User guide manual
connection plate (1)
(1)
Downdraft unit (1)
https://producthelp.fisherpaykel.com/us/Cook/Ventilation/Downdraft/HD36/User_Guide_HD36/05_installation_instructions
Updated: Fri, 28 Jun 2019 03:30:59 GMT
Powered by
1

Advertisement

Table of Contents
loading

Summary of Contents for Fisher & Paykel HD30

  • Page 1 Installation Instructions Downdraft Unit Contents of Packaging End cap (2) Installation instructions 10” (254 mm) remote blower User guide manual connection plate (1) Downdraft unit (1) https://producthelp.fisherpaykel.com/us/Cook/Ventilation/Downdraft/HD36/User_Guide_HD36/05_installation_instructions Updated: Fri, 28 Jun 2019 03:30:59 GMT Powered by...
  • Page 2 Under counter Top trim (1) mounting bracket (2) Grease filter (2) Support leg mounting bracket (2) 5/16" (8 mm) 9/32" (7 mm) nut (2) 3/16" (5 mm) screw (2) screw (6) Over counter monting bracket 19/32” (15 mm) Self tapping screw (6) https://producthelp.fisherpaykel.com/us/Cook/Ventilation/Downdraft/HD36/User_Guide_HD36/05_installation_instructions Updated: Fri, 28 Jun 2019 03:30:59 GMT Powered by...
  • Page 3: Internal Blower (Hbd600I) Contents Of Packaging

    Internal Blower (HBD600I) Contents of Packaging 6” (152 mm) diameter back draft damper (1) Internal blower box (1) Remote Blower (HBD1200E) Contents of Packaging Remote blower (1) Duct collar plate (1) https://producthelp.fisherpaykel.com/us/Cook/Ventilation/Downdraft/HD36/User_Guide_HD36/05_installation_instructions Updated: Fri, 28 Jun 2019 03:30:59 GMT Powered by...
  • Page 4: Product Dimensions

    Remote blower (HBD1200E) Remote blower connection plate (can also be mounted on the back of appliance) Downdraft unit and internal blower box (HBD600I) which can also be mounted on the back of the appliance HD30 HD36 Product Dimensions inches (mm) inches (mm) A.
  • Page 5: Cabinet Cutout Dimensions

    HD30 HD36 Product Dimensions inches (mm) inches (mm) Length of power cord • Actual product dimensions may vary by ± 3/32” (2 mm). • Please read the entire instructions before installing the downdraft vent system. Cabinet Cutout Dimensions CUTOUT LOCATION A.
  • Page 6: Compatible Blowers With The Downdraft Vent System

    B. Internal blower down 6” (152 mm) ducting C. Internal blower rear 6” (152 mm) ducting D. Remote blower power cord cutout down or to the rear E. Remote blower rear 10” (254 mm) ducting F. Cooktop overhang HD30 HD36 Installation Dimensions inches (mm) inches (mm) G.
  • Page 7: Venting Requirements

    may require additional space behind the range for oven venting OR with freestanding ranges WITH backguards. Always consult all product installation instructions for correct dimensions and clearances. Make certain any cooktop installed is appropriate for use with a downdraft vent system. Venting Requirements Attention should be given to ensure that any applicable regulations concerning the discharge of exhaust air are fulfilled.
  • Page 8: Preparing For Installation

    flexible metal ductwork is equivalent to two feet (617 mm) of straight metal ductwork when calculating the duct run length. For best results the size of the ductwork should be uniform and use no more than three 90° elbows. Make sure that there is a minimum of 24”...
  • Page 9: Prepare The Downdraft Unit For The Intended Blower

    • Please read the instructions carefully. • Unpack the downdraft unit and place on a flat protected surface. • Ensure the voltage (V) and the frequency (Hz) indicated on the serial plate match • the voltage and frequency of the installation site. •...
  • Page 10: Temporarily Insert The Downdraft Into The Cabinet

    Fig.1 Fig.3 Fig.4 3. Temporarily Insert the Downdraft into the Cabinet • With the assistance of another person, lift the downdraft unit into the prepared cutout in the cabinet. The over counter mounting brackets should rest on the countertop. • Secure the downdraft unit to the countertop with two 19/32” (15 mm) screws. •...
  • Page 11: Remove The Downdraft From The Cabinet

    Failure to follow these instructions could result in damage to the countertop surface. • Level and align the downdraft unit in the cabinet. Push the support leg mounting bracket on each side down against the cabinet floor. Mark the top edge of the mounting bracket on the downdraft unit and the mounting holes on the cabinet floor Fig.6.
  • Page 12: Install The Internal Or Remote Blower

    5. Install the Internal or Remote Blower • For internal blower installation. • For remote blower installation. This downdraft unit may only be used in connection with DCS internal or remote blowers. Internal Blower Installation in One of the Following Two Options: Option 1: Internal blower, front installation for venting left, right or down •...
  • Page 13 • Continue to the ‘Prepare for electrical connection’ section. Fig.9 Fig.10 Fig.11 Remote Blower Installation in One of the Following Three Options: • Make sure that the discharge end of the remote blower faces away from the direction of the prevailing winds.
  • Page 14 • Run a large bead of caulk on the back side of the housing along the outer edge. • Center the remote blower ring in the 11” (279 mm) diameter hole, making sure that the 1 1/4” (32 mm) diameter electrical wiring hole lines up with the hole in the wiring box. •...
  • Page 15 • Attach the remote blower to roof or frame using screws appropriate for your installation. All four holes in the back panel must be filled to prevent moisture that may get inside the remote blower housing from leaking into the home. •...
  • Page 16 6. Prepare for Electrical Connection Downdraft Unit • Remove the cover of the terminal box from the downdraft unit Fig.14. • Decide whether the power source should enter the downdraft unit from below or from the back and remove the respective knock out. Install a UL listed strain relief or conduit fitting (not included) in the knock out Fig.15.
  • Page 17: Electrical Connection

    Fig.17 7. Electrical Connection ◦ Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards and the unit must be grounded. ◦ This downdraft unit may only be used in connection with DCS internal or remote blowers. ◦...
  • Page 18 This appliance should be connected directly to the fuse disconnect (or circuit breaker) through flexible, armored or non-metallic sheathed copper cable. Allow some slack in the cable so the appliance can be moved if servicing is ever necessary. A UL Listed strain relief or 1/2” (12.7 mm) conduit connector must be provided at each end of the power supply cable (at the appliance and at the junction box).
  • Page 19 Fig.19 Fig.20 Downdraft Unit Remote Blower Electrical Connection • Connect the power supply cable into the box as described in the ‘Downdraft unit internal blower electrical connection’ section (above). • To use a remote blower, install a control cable between the downdraft unit and the remote blower. See the ‘Remote blower electrical connection’...
  • Page 20 Remote Blower Electrical Connection • Remove the cover from the remote blower, then remove the wiring box cover. • Pull the electrical wiring through the hole in the blower base and secure it according to local codes using a suitable UL listed strain relief or conduit fitting (not included). •...
  • Page 21: Complete The Installation

    8. Complete the Installation • Place the top trim onto the downdraft unit. • Push the power button on the top trim, the downdraft unit will rise. (The blower will begin to vent immediately if the blower control slider is set to an ‘On’ position). •...
  • Page 22: Attach The Ducting

    Fig.25 9. Attach the Ducting • For the internal blower box, use 6” (152 mm) round ducting and the 6” (152 mm) diameter back draft damper. • For the remote blower, use 10” (254 mm) round ducting. • Attach ducting using clamps or aluminum duct tape to seal all joints and vent outside. 10.