Swing Flap Motor; Checking Procedures; Repair Procedures; Thermistors - Daikin Comfora FTXP20~71L2V1B Service Manual

Split comfora r32 series
Table of Contents

Advertisement

2.12

Swing flap motor

NOTICE
Select the correct type.
2.12.1

Checking procedures

To perform an electrical check of the swing flap
motor
Prerequisite: Turn OFF the unit via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
work" on
page 35.
1 Disconnect the motor connector from the indoor unit PCB.
2 Measure the resistance between the following pins of the motor
connector. The measurements MUST be as shown in the table
below.
Pins
1-2
1-3
1-4
1-5
2-3
2-4
2-5
3-4
3-5
4-5
Swing flap motor resistance
measurements are correct?
Yes
No
2.12.2

Repair procedures

To remove the swing flap motor
Prerequisite: Turn OFF the unit via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
work" on
page 35.
1 Remove the cover.
ATXP20~35L2V1B + FTXP20~71L2V1B + ARXP20~35L2V1B +
RXP20~71L2V1B
Split Comfora R32
ESIE18-01 – 2019.02
"2.10  Plate
Measured resistance (Ω)
235
470
Action
Return to the troubleshooting of
the specific error and continue
with the next procedure.
Replace the swing flap motor,
see
"2.12.2 Repair
procedures" on
page 41.
"2.10  Plate
b
c
a
Cover
b
Screw
c
Swing flap motor
2 Disconnect the connector from the swing flap motor.
3 Remove the screw from the swing flap motor.
4 Remove the swing flap motor from the swing flap.
5 To
install
the
swing
procedures" on
page 41.
To install the swing flap motor
1 Install the swing flap motor in the correct location on the swing
flap.
b
c
a
Cover
b
Screw
c
Swing flap motor
2 Install and tighten the screw to fix the swing flap motor.
3 Connect the connector to the swing flap motor.
4 Install the cover.
Is the problem solved?
Yes
No
2.13

Thermistors

NOTICE
Select the correct type.
2 Components
a
flap
motor,
see
"2.12.2  Repair
a
Action
No further actions required.
Return to the troubleshooting of
the specific error and continue
with the next procedure.
Service manual