Allow Access - Siemens SCALANCE S615 Getting Started

Industrial ethernet security
Hide thumbs Also See for SCALANCE S615:
Table of Contents

Advertisement

2.2.3

Allow access

So that the PC can access the SINEMA RC Server, access from vlan1 to vlan2 is enabled
on the device.
Procedure
1. Click on "Security" > "Firewall" in the navigation area and on the "IP Rules" tab in the
content area.
2. Click "Create". A new entry is created in the table.
3. Configure the firewall rule with the following settings:
4. Click "Set Values".
Result
Due to this firewall rule, all services between vlan1 and vlan2 are possible without
restrictions, e.g. HTTPS
SCALANCE S615 Getting Started
Getting Started, 03/2015, C79000-G8900-C390-01
OpenVPN tunnel between SCALANCE S615 and SINEMA RC Server
Action
From
To
Source (Range)
Destination (Range)
Service
2.2 Configuring access to the SINEMA RC Serve
Accept
vlan1 (internal)
vlan2 (external)
0.0.0.0 (all IP addresses)
0.0.0.0 (all IP addresses)
all
As default, the service is always available