Water inlet fault

Problem
The optical in-operation
indicator light is flash-
ing quickly.
The alarm tone is
sounding.
One of the following
messages appears in
the display:
 
Please open the stop-
cock
 
Insufficient water intake.
Open the stopcock fully.
Refer to operating instruc-
tions if necessary
The following fault mes-
sage appears during the
 programme:
SolarSave
Intake temperature too low
Cause and remedy
The stopcock is closed.
 Open the stopcock fully.
Before rectifying the problem:
 Switch the dishwasher off.
The water inlet is restricted.
 Open the stopcock fully and start the programme
again.
 Clean the filter in the water inlet (see "Cleaning
and care" chapter, "Cleaning the filter in the water
inlet" section).
 The water-connection pressure is lower than
50 kPa.
Seek professional advice.
 The on-site connection for the water drainage may
be too low and you will need to vent the water
drainage (see "Installation" chapter, "Water drain-
age" section).
The inlet water has not reached the required temper-
ature of 45 °C (see "Installation" chapter, "Water inlet"
section).
 Start the programme again.
 If the fault message appears again, select a differ-
ent programme.