Ball Oilers
Oil Type ......Model T23963 or ISO 32 Equivalent
Oil Amount ......................................... 1–2 Pumps
Lubrication Frequency ........8 Hours of Operation
This machine has four ball oilers, as shown in
Figures 41–42. Use an oil gun fitted with a tip
wide enough to seal the ball oiler inlet. We do
not recommend using metal needle or lance-type
tips, as they can push the ball too far into the oiler,
break the spring seat, and lodge the ball in the oil
galley.
Push the tip of the oil can nozzle against the ball
oiler to create a hydraulic seal, then pump the oil
can once or twice. If you see sludge and contami-
nants coming out of the lubrication area, continue
pumping the oil can until the oil runs clear. When
finished, wipe away the excess oil.
Ball Oilers
Figure 41. Table support bracket ball oiler
locations.
Ball Oilers
Figure 42. Headstock ball oiler locations
Model G0793 (Mfd. Since 02/15)
Column Rack
Grease Type ......... NLGI#2 Grease or Equivalent
Grease Amount ....................................Thin Coat
Lubrication Frequency ......... 90 hrs. of Operation
Move the table up and down to gain full access to
the column racks (see Figures 43), then clean the
teeth with mineral spirits, shop rags, and a brush.
Figure 43. Column rack location.
When dry, use a brush to apply a thin coat of
grease to the teeth, then raise/lower the head-
stock and table to distribute the grease.
Note: To help prevent rust, re-apply ISO 32 oil to
the column smooth surfaces that were removed
during the cleaning process.