Download Print this page

Harman Stove Company Accentra Service Training page 22

Includes all pellet burning units

Advertisement

Remove draft test plug bolt. (9/16 wrench)
Remove hose from draft meter
With meter standing vertical, adjust needle to zero
Hook up the test hose to the "low" port on the meter this is
the port for measuring negative pressure
Attach the other end of the hose to the test port on the stove
using the bolt-tube fitting supplied in the kit
Turn feed rate knob to "Turbo" All motors will run on high.
Record high draft reading (.5" W.C.or more)
Turn Feed Rate knob to #1 and allow the unit to run for
about a minute, record the low draft reading (.15"W.C. to
.20" W.C.)
Adjust pot on back of circuit board if needed
Turn Feed Rate knob to "off"
Remove hose from stove port
Replace draft test plug bolt
Draft Test Procedure
For PP38 +
Harman Pellet Service Training
22