Sony Digital betacam DVW-970 Operation Manual page 123

Sony digital camcorder operation manuals dvw-970, dvw-970p
Hide thumbs Also See for Digital betacam DVW-970:
Table of Contents

Advertisement

Non-volatile memory
Independent data
region
MASTER BLACK
MASTER GAMMA
KNEE POINT
Setup
DETAIL LEVEL
menu of the
R/B GAIN
camcorder
R/B BLACK
Remote control data
RM-B150
region
MASTER BLACK
MASTER GAMMA
KNEE POINT
DETAIL LEVEL
R/B GAIN
R/B BLACK
Thus, when a remote control unit is connected to the
camcorder, the effective data region is switched to the
"remote control data region" and the settings of the paint
adjustment that were in effect last time the remote control
unit was used are recalled.
Settings of the absolute value volume
2)
switches
are overwritten by those on the remote control
unit after the remote control unit is connected.
When the remote control unit is removed from the
camcorder, the "independent data region" becomes
effective. Thus the camcorder will return to the settings
that were in effect before the remote control unit was
connected.
1) Absolute value volume
The data corresponding to the rotation degree (position) of the volume
knob is output. The data corresponding to the rotation amount (change) is
called the relative value volume.
2) Absolute value switch
Toggle switches or slide switches (except the temporary switches) (or
controls) whose positions must coincide with their functions are called
absolute value switches.
To use settings of the paint adjustment data
stored in the "independent data region" even
when you disconnect a remote control unit
Set RM COMMON MEMORY to ON on the FUNCTION
3 page of the MAINTENANCE menu.
In this case, the settings stored in the "independent data
region" will be renewed according to the change of settings
in the "remote control data region." Thus, the settings of
the paint data made with the remote control unit can be
retained even if the remote control unit is removed.
However, if the switch position on the remote control unit
differs from the one on the camcorder, the switch position
on the camcorder takes precedence over that on the remote
control unit.
For details on menu operations, see "5-1-2 Basic Menu
Operations" on page 71.
To keep the video quality before a remote control
unit is connected
Set RM COMMON MEMORY to ON on the FUNCTION
3 menu of the MAINTENANCE menu, and set all the
volume on the remote control unit to the relative value
mode. After making these settings, connect the remote
control unit.
Hardware of
For details, refer to the operation manual supplied with the
the camera
remote control unit.
RM-B150
connected
RM-B150 not
connected
1)
and absolute value
Connecting the Remote Control Unit
123

Advertisement

Table of Contents
loading

This manual is also suitable for:

Digital betacam dvw-970pMsw-970Msw-970pDvw-970Dvw-970p

Table of Contents