Control Word Block Selection - Siemens SINAMICS G120 Function Manual

Low-voltage inverter; basic positioner (epos) for cu250-2 control units
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Basic positioner
3.3 PROFIdrive interfaces
3.3.6

Control word block selection

Block selection
Table 3- 14
Block selection and interconnection in the converter
Bit
Meaning
0
Block selection, bit 0
1
Block selection, bit 1
2
Block selection, bit 2
3
Block selection, bit 3
4...14
Reserved
15
0 = Deactivate MDI
1 = Activate MDI
Actual traversing block
Table 3- 15
Feedback signal of the actual traversing block
Bit
Meaning
0
Actual traversing block, bit 0
1
Actual traversing block, bit 1
2
Actual traversing block, bit 2
3
Actual traversing block, bit 3
4...14
Reserved
15
0 = MDI active
1 = MDI not active
26
Comments
Example for selecting
traversing block number
5:
Switching from traversing blocks to direct setpoint
input.
Comments
---
---
Function Manual, 04/2015, FW V4.7 SP3, A5E34257659B AB
P No.
p2625 = r2091.0
p2626 = r2091.1
p2627 = r2091.2
p2628 = r2091.3
p2647 = r2091.15
P No.
p2081[0] = r2670.0
p2081[1] = r2670.1
p2081[2] = r2670.2
p2081[3] = r2670.3
p2081[15] = r2670.15
Basic positioner