14.6.2 Errors with function 2, "division increment"

Error
Error meaning
number
100
Axis number not allowed for this
(64
)
mode group or NC channel
H
101
Incorrect mode
(65
)
H
102
Channel already assigned
(66
)
H
103
No NC stop state
(67
)
(safety function for AUTOMATIC)
H
104
No NC stop or no read-in enable
(68
)
(without safety function for AUTOMATIC)
H
105
Axis already active in another channel
(69
)
H
106
User data length not equal to 5
(6A
)
H
107
Impermissible user data
(6B
)
H
108
Option not available
(6C
)
H
109
Incorrect division increment, i.e. division increment > number of divisions
(6D
)
(G90), division number too great with rotary axes, C axis is not indexing
H
axis (G91)
110
Block search active
(6E
)
H
200
Abort by: Reset, mode change, emergency stop, warm restart, servo
(C8
)
disable, NC alarms, follow-up mode, parking axis, coupled motion, transmit,
H
position behind software limit switch, etc.