2.7.16

Set actual value (PRESETON)

Function
The actual value can be redefined in the machine coordinate system (MCS) for machine
axes with
PRESETON
● Modulo rotary axes that were started from the part program
● Command axes that were started from synchronized actions
By setting a new actual value in the machine coordinate system, the reference point of the
machine axis becomes invalid. For this reason it is recommended that
used for axes that do not require a reference point.
To restore the original machine coordinate system, the measuring system of the machine
axis must be referenced again, e.g. through active referencing from the part program (
Syntax
WHEN | EVERY ... DO PRESETON(<axis>,<value>)
Meaning
PRESETON
<axis>
<value>
Synchronized actions
Function Manual, 07/2012, 6FC5397-5BP40-3BA0
. In this mode, the axes are not traversed.
PRESETON
is possible in synchronized actions for the following axis types:
CAUTION
:
Preset actual-value memory
:
Machine axis identifier
Range of values: Machine axis identifier defined in the channel
:
New actual value of the machine axis in the machine coordinate system
(MCS)
Detailed description
2.7 Actions in synchronized actions
PRESETON
only be
).