Load Gear: Position Tracking Actual Position Outside Tolerance Window; Drive: Power Unit Data Set Pds Not Configured - Siemens SINAMICS S210 Operating Instructions Manual

Servo drive system
Hide thumbs Also See for SINAMICS S210:
Table of Contents

Advertisement

Remedy:
- reduce the fine resolution (p0419).
- reduce the multiturn resolution (p2721).
F07448 (A)
Load gear: Position tracking, linear axis has exceeded the maximum range
Message value:
-
Drive object:
All objects
Reaction:
Servo: OFF1 (NONE, OFF2, OFF3)
Acknowledge:
IMMEDIATELY
Cause:
For a configured linear axis/no modulo axis, the currently effective motor encoder (encoder 1) has exceeded the maximum
possible traversing range.
For the configured linear axis, the maximum traversing range is defined to be 64x (+/- 32x) of p0421. It should be read in
p2721 and interpreted as the number of load revolutions.
Note:
Only the motor encoder in the currently effective drive data set is monitored here. The actual effective drive data set is
displayed in x = r0051 and the corresponding motor encoder is specified in in p0187[x].
Remedy:
The fault should be resolved as follows:
- select encoder commissioning (p0010 = 4).
- reset position tracking, position (p2720.2 = 1).
- deselect encoder commissioning (p0010 = 0).
The fault should then be acknowledged and the absolute encoder adjusted.
Reaction upon A: NONE
Acknowl. upon A: NONE
F07449 (A)

Load gear: Position tracking actual position outside tolerance window

Message value:
%1
Drive object:
All objects
Reaction:
Servo: OFF1 (NONE, OFF2, OFF3)
Acknowledge:
IMMEDIATELY
Cause:
When switched off, the currently effective motor encoder was moved through a distance greater than was parameterized
in the tolerance window. It is possible that there is no longer any reference between the mechanical system and encoder.
Note:
Only the motor encoder in the currently effective drive data set is monitored here. The actual effective drive data set is
displayed in x = r0051 and the corresponding motor encoder is specified in in p0187[x].
Fault value (r0949, interpret decimal):
Deviation (difference) to the last encoder position in increments of the absolute value after the measuring gear - if one is
being used. The sign designates the traversing direction.
Note:
The deviation (difference) found is also displayed in r2724.
Remedy:
Reset the position tracking as follows:
- select encoder commissioning (p0010 = 4).
- reset position tracking, position (p2720.2 = 1).
- deselect encoder commissioning (p0010 = 0).
The fault should then be acknowledged and, if necessary, the absolute encoder adjusted (p2507).
See also: p0010
Reaction upon A: NONE
Acknowl. upon A: NONE
F07500

Drive: Power unit data set PDS not configured

Message value:
Drive data set: %1
Drive object:
All objects
Reaction:
NONE
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
Faults and alarms
13.2 List of faults and alarms
447

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics s-1fk2

Table of Contents