Technical Data; Specifications - Siemens Milltronics MUS Operating Instructions Manual

Belt scale
Table of Contents

Advertisement

Technical data

8.1

Specifications

Accuracy
± 0.5% of totalization over 25 to 100% operating range
Accuracy subject to: On factory approved installations the belt scale systems totalized weight will be within the specified
accuracy when compared to a known weighed material test sample. The test rate must be within the specified range of
the design capacity and held constant for the duration of the test. The minimum material test sample must be equivalent
to a sample obtained at the test flow rate for three revolutions of the belt or at least ten minutes running time, whichever
is greater.
Load Cell
Construction
Enclosure
Excitation
Output
Non-linearity
Hysteresis
Non-repeatability
Capacity
Overload
Temperature
Belt width
standard duty: up to 1000 mm (CEMA width up to 42 ")
heavy duty: up to 1500 mm (CEMA width up to 60")
refer to Outline Dimensions
Milltronics MUS
Operating Instructions, 06/2012, 7ML19985CQ02-02
Nickel plated alloy steel
IP66 rated
10 V DC nominal, 15 V DC maximum
2 mV / V excitation at rated load cell capacity
0.02% of rated output
0.02% of rated output
0.01% of rated output
standard duty ranges: 20, 30, 50, 75, 100 kg
heavy duty ranges: 50, 100, 150, 200, 500 kg
150% of rated capacity
ultimate 200% of rated capacity
-40 to +65 °C (-40 to +150 °F) operating range
-10 to +40 °C (+15 to +105 °F) compensated
8
39