Technical Data; Specifications - Siemens Milltronics WD600 Operating Instructions Manual

Belt scales
Hide thumbs Also See for Milltronics WD600:
Table of Contents

Advertisement

Technical data

8.1

Specifications

Accuracy
± 0.5% or better of totalization over 25 to 100% operating range
Accuracy subject to: On factory approved installations the belt scale systems totalized weight will be
within the specified accuracy when compared to a known weighed material test sample. The test
rate must be within the specified range of the design capacity and held constant for the duration of
the test. The minimum material test sample must be equivalent to a sample obtained at the test
flow rate for three revolutions of the belt or at least ten minutes running time, whichever is greater.
Load Cell
construction
degree of protection
excitation
output
non-linearity
hysteresis
non-repeatability
capacity
overload
temperature
Belt width
300 to 1200 mm (12 to 48")
Refer to Outline dimensions (Page 29)
Milltronics WD600
Operating Instructions, 09/2016, A5E38964753_AB
nickel plated alloy steel or 17-4 PH (1.4568)
stainless steel
IP66 rated (nickel plated)
IP68 rated (stainless steel)
10 V DC nominal, 15 V DC maximum
2 mV/V excitation at rated load cell capacity
0.02% of rated output
0.02% of rated output
0.01% of rated output
nickel plated maximum ranges: 10, 15, 20, 30, 50
kg
stainless steel maximum ranges: 6, 12, 30 kg
150% of rated capacity
ultimate 300% of rated capacity
–40 to +65 °C (– 40 to +150 °F) operating range
–10 to +40 °C (–15 to +105 °F) compensated
8
27

Advertisement

Table of Contents
loading

Table of Contents