Hoshizaki KM-40B Service Manual page 56

Self-contained crescent cuber
Hide thumbs Also See for KM-40B:
Table of Contents

Advertisement

Wrap this part with a
damp cloth to prevent
overheating
Remove band
from Bulb with
a screwdriver
Top Rear View with Top and Rear Panels Removed
Bulb
Remove Expansion
Valve Cover first
Bulb Insulation Hose
Expansion Valve
Fig. 5
52
Cut ties to make Bulb
removable
Expansion Valve is brazed at
these two points.
While brazing, remove In-
sulation Hoses from pipes
and keep brazing equipment
away from other parts to
prevent burning.