Program Values - Bosch Therm 6000 S Installation And Operating Instructions Manual

Table of Contents

Advertisement

8.4

Program values

This section describes details on programming the appliance.
For most applications the factory default values will provide
robust and stable operation.
Program
Description
P1
Maximum Power
P2
Minimum Power
P3
Remote
Controls installed
P4
Access to
Diagnostic Mode
P5
Cascade Mode
P6
Temperature Unit °C
P7
Appliance Type
P8
Back light
P9
Fan Purge
PH
Cascading type
PC
Master/Slave
mode
Table 12
Therm 6000S
Factory default
Min
N. Gas: 40
21
LPG: 37
N. Gas: 8
N. Gas: 8
LPG: 7
LPG: 7
_0
_0
E
0d
nO
nO
°F
nO
Cd
(condensing)
dE
dE
IC
IC
CS
CS
CAUTION: Misadjusted program values
can lead to appliance malfunction, errors,
and service calls.
Max
Comment
N. Gas: 40
See chapter 8.2.
LPG: 37
Note: reducing P1 values below maximum
will reduce maximum power of the
appliance.
20
See chapter 8.2.
6
See chapter 4.6.
10f
See chapter 8.5.
CC
To activate the cascade mode it's necessary
to install the "kit cascade" (cod. 7 736 500
272)
°C
See chapter 8.5.
nO
Condensing / Non-condensing
note: incorrect setting will cause errors.
On
dE: turns back light off after 60 seconds
from last button pushed.
ON: turns backlight on permanently.
Runs secondary fan and primary fan when
P9 is selected by depressing the "P" - button
SC
This menu is only available when cascade
mode is selected CC.
Cn
Installation instructions | 29
6 720 800 095 (2015/11)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents