▶ Check the fuses in the printed circuit board, see Fig. 40,
[3].
2
Fig. 40
Fuses position
▶ After checking the fuses, reinstall all parts in reverse order
(Fig. 40, [3]).
8
Installation instructions
8.1
Factory regulations
Sealed parts must not be interfered with.
Natural gas
Heaters designed for Natural gas H (G 20) are factory sealed for
delivery after the values on the characteristics panel have been
checked.
Heaters should not be ignited when the
connections pressure is less than 1,5 kPa
more than 2,5 kPa.
Liquid gas
Butane heaters (G30) are factory sealed for delivery after the
values on the characteristics panel have been checked.
Therm 6000S
1
3
6720608158-78.1AL
DANGER:
▶ The following operations must be
carried out by a qualified technician.
8.2
Measuring gas pressure
Confirm gas pressure after installation.
Connecting manometer
▶ Shut off gas supply.
▶ Remove the front cover Fig. 23 .
▶ Loosen screw inside left test point fitting (do not remove)
and connect manometer tube to test point.
Fig. 41
Gas pressure test port (left tapping)
Static Pressure Test
▶ Turn gas supply back on.
▶ Record static gas pressure reading in Table 7 .
Static Gas Pressure Reading
Pressure: ___________________ Date: ___________
Operating Gas Pressure Reading
Pressure: ___________________ Date: ___________
Table 7
Operating Pressure Test
▶ Press ON/OFF button to turn off the appliance.
Installation instructions | 25
6 720 800 095 (2015/11)