7.5

Program values

This section describes details on programming the appliance.
For most applications the factory default values will provide
robust and stable operation. Only adjust the factory settings if
the installation requires changes as indicated in the
appropriate section of this manual.
Refer to chapter 7.6 Control board diagnostics (page 57)
regarding how to access these P-modes.
Program Description
P1
Maximum Power
P2
Minimum Power
P3
Remote
Controls installed
P4
Access to
Diagnostic Mode
P5
Cascade Mode
P6
Temperature Unit
P7
Gas type selection
P9
Fan Purge
PH
Cascading type
PC
Primary/Secondary
mode
Table 37 Program values, factory default settings and ranges.
56
Factory Default MIN
NG: 48,
21
LP: 40
7
7
_0
_0
E
0d
NO
NO
°F
°F
LP or NG
IC
IC
CS
CS
CAUTION:
Appliance malfunction!
▶ Misadjusted program values can lead to appliance
malfunction, errors, and service calls.
MAX
Comment
NG: 49,
See chapter 4.14, page 46
LP: 41
note: reducing P1 values below maximum will reduce
maximum power of the appliance.
20
see chapter 4.3.8, page 30
6
see chapter 6.5, page 50
10f
see chapter 7.6, page 57
CC
contact Bosch for details
°C
Preset from factory.
Contact Bosch for details.
Runs secondary fan and primary fan when P9 is
selected by depressing the "P" - button
SC
This menu is only available when cascade mode is
selected CC.
Contact Bosch Water Heating for details.
Cn
830 ES – 6 720 644 936 (2021/08)