Program Values - Bosch AquaStar GWH 2700 ES NG Manual

Temperature modulated with electronic ignition
Table of Contents

Advertisement

6.5

Program values

This section describes details on programming the
appliance. For most applications the factory default
values will robust and stable operation. Only adjust the
factory settings if the installation requires changes as
indicated in the appropriate section of this manual.
Program
Description
P1
Maximum Power
P2
Minimum Power
P3
Remote Con-
trols installed
P4
Access to Diag-
nostic Mode
P5
Cascade Mode
P6
Temperature
Unit
P7
Appliance Type
P8
Back light
P9
Fan Purge
Table 15 Program values, factory default settings and ranges.
* Incorrect setting causes errors.
6 720 608 542
Factory Default
MIN
NG:45, LP:44
21
6
6
_0
_0
E
0d
NO
NO
°F
°F
NO
Cd
dE
dE
Refer to chapter 6.6 Control board diagnostics (page
32) regarding how to access these P-modes.
Caution:
Misadjusted
values
can
malfunction, errors, and service
calls.
MAX
Comment
NG:45, LP:44
see chapter 3.12, page 22.
note: reducing P1 values below
maximum will reduce maximum
power of the appliance.
20
see chapter 6.7, page 33
6
see chapter 5.5, page 26
10f
see chapter 6.6, page 32
CC
contact Bosch for details
°C
NO
Condensing / Non-condensing*
ON
dE turns back light off after 60
seconds from last button pushed,
ON
permanently
runs secondary fan when P9 is
selected by depressing the "P" -
button
Maintenance and service
program
lead
to
appliance
turns
backlight
on
31

Advertisement