Product Certifications
ATEX Intrinsic Safety
Certificate: [Headmount HART]: Baseefa12ATEX0101X
[Headmount Fieldbus/PROFIBUS]: Baseefa03ATEX0499X
[Railmount HART]: BAS00ATEX1033X
Standards: EN 60079-0: 2012, EN 60079-11: 2012
Markings: [HART]:
II 1 G Ex ia IIC T6...T4 Ga; [Fieldbus/Profibus]:
See
Table B-2
for Entity Parameters and Temperature Classifications.
The equipment must be installed in an enclosure which affords it a degree of protection
of at least IP20 in accordance with the requirements of IEC 60529. Non-metallic
enclosures must have a surface resistance of less than 1GΩ; light alloy or zirconium
enclosures must be protected from impact and friction when installed in a Zone 0
environment.
When fitted with the Transient Protector Assembly, the equipment is not capable of
withstanding the 500V test as defined in Clause 6.3.13 of EN 60079-11:2012. This must
be taken into account during installation.
ATEX Type n - with enclosure
Certificate: BAS00ATEX3145
Standards: EN 60079-0: 2012, EN 60079-15: 2010
Markings: II 3 G Ex nA IIC T5 Gc (-40 °C
ATEX Type n - without enclosure
Certificate: [Headmount Fieldbus/Profibus, Railmount HART]: Baseefa13ATEX0093X
[Headmount HART]: Baseefa12ATEX0102U.
Standards: EN 60079-0: 2012, EN 60079-15: 2010
Markings: [Headmount Fieldbus/Profibus, Railmount HART]:
(-40 °C
Ta
+70 °C) [Headmount HART]:
(-60 °C
Ta
+40 °C);T5(-60 °C
The Model 644 Temperature Transmitter must be installed in a suitably certified enclosure
such that it is afforded a degree of protection of at least IP54 in accordance with IEC 60529
and EN 60079-15.
When fitted with the Transient Protector Assembly, the equipment is not capable of
withstanding the 500V test as defined in Clause 6.3.13 of EN 60079-11:2012. This must
be taken into account during installation.
ATEX Dust
Certificate: FM12ATEX0065X
Standards: EN 60079-0: 2012, EN 60079-31: 2009, EN 60529:1991 +A1:2000
Markings:
II 2 D Ex tb IIIC T130 °C Db, (-40 °C
See
Table B-1
for process temperatures
Appendix B: Product Certifications
Ta
+70 °C)
II 3 G Ex nA IIC T6...T5 Gc; T6
Ta
+85 °C)
Ta
+70 °C); IP66
April 2015
II 1 G Ex ia IIC T4 Ga;
II 3 G Ex nA IIC T5 Gc