Table A-2. Rosemount 644 Input Options and Accuracy
Sensor options
Sensor reference
Cu 50 (α = 0.00428)
Cu 100 (α = 0.00426)
Cu 100 (α = 0.00428)
(4)
Thermocouples
(5)
Type B
NIST Monograph 175, IEC 584
Type E
NIST Monograph 175, IEC 584
Type J
NIST Monograph 175, IEC 584
(6)
Type K
NIST Monograph 175, IEC 584
Type N
NIST Monograph 175, IEC 584
Type R
NIST Monograph 175, IEC 584
Type S
NIST Monograph 175, IEC 584
Type T
NIST Monograph 175, IEC 584
DIN Type L
DIN Type U
Type W5Re/W26Re
GOST Type L
GOST R 8.585-2001
Other input types
Millivolt Input
2-, 3-, 4-wire Ohm Input
(1) No minimum or maximum span restrictions within the input ranges. Recommended minimum span will hold noise within accuracy specification with
damping at zero seconds.
(2) The published digital accuracy applies over the entire sensor input range. Digital output can be accessed by HART or F
or Rosemount control system.
(3) Total Analog accuracy is the sum of digital and D/A accuracies. This is not applicable for F
(4) Total digital accuracy for thermocouple measurement: sum of digital accuracy +0.5 °C. (cold junction accuracy).
(5) Digital accuracy for NIST Type B T/C is ±3.0 °C (±5.4 °F) from 100 to 300 °C (212 to 572 °F).
(6) Digital accuracy for NIST Type K T/C is ±0.70 °C (±1.26 °F) from –180 to –90 °C (–292 to –130 °F).
Specifications and Reference Data
Input ranges
GOST 6651-94
–185 to 200
GOST 6651-94
–50 to 200
GOST 6651-94
–185 to 200
100 to 1820
–50 to 1000
–180 to 760
–180 to 1372
–200 to 1300
0 to 1768
0 to 1768
–200 to 400
DIN 43710
–200 to 900
DIN 43710
–200 to 900
ASTM E 988-96
0 to 2000
–200 to 800
–10 to 100 mV
0 to 2000 ohms
Appendix A: Specifications and Reference Data
Recommended
(1)
min. span
–301 to 392
10
18
–58 to 392
10
18
–301 to 392
10
18
212 to 3308
25
45
–58 to 1832
25
45
–292 to 1400
25
45
–292 to 2501
25
45
–328 to 2372
25
45
32 to 3214
25
45
32 to 3214
25
45
–328 to 752
25
45
–328 to 1652
25
45
–328 to 1112
25
45
32 to 3632
25
45
–328 to 1472
25
45
fieldbus.
OUNDATION
April 2015
(2)
Digital accuracy
D/A accuracy
±1.34
± 2.41
±0.03% of span
±0.67
± 1.20
±0.03% of span
±0.67
± 1.20
±0.03% of span
± 0.77
± 1.39
±0.03% of span
± 0.20
± 0.36
±0.03% of span
± 0.35
± 0.63
±0.03% of span
± 0.50
± 0.90
±0.03% of span
± 0.50
± 0.90
±0.03% of span
± 0.75
± 1.35
±0.03% of span
± 0.70
± 1.26
±0.03% of span
± 0.35
± 0.63
±0.03% of span
± 0.35
± 0.63
±0.03% of span
± 0.35
± 0.63
±0.03% of span
± 0.70
± 1.26
±0.03% of span
± 1.00
± 1.26
±0.03% of span
±0.015 mV
±0.03% of span
±0.45 ohm
±0.03% of span
fieldbus Communications
OUNDATION
(3)
99