Kenwood TK-3312 Service Manual page 32

Uhf fm transceiver
Hide thumbs Also See for TK-3312:
Table of Contents

Advertisement

TK-3312/3317
Item
Condition
6. DQT
1) TEST CH: 1
Deviation
Deviation meter filter
[Wide]
LPF: 3kHz
HPF: OFF
PTT: ON
7. QT
1) TEST CH: 1
Deviation
Deviation meter filter
[Wide]
LPF: 3kHz
HPF: OFF
PTT: ON
8. DTMF
1) TEST CH: 1
Deviation
LPF: 15kHz
HPF: OFF
[Wide]
PTT: ON
9. MSK
1) TEST CH: 1
Deviation
Deviation meter filter
[Wide]
LPF: 15kHz
HPF: OFF
PTT: ON
Note: Regarding deviation alignment item, narrow value is calculated from wide alignment value.
Receiver Section
Item
Condition
1. Sensitivity
1) TEST CH: Low, Center, High
(Semiauto-
(3 points)
matic)
SSG otuput : –90dBm
(7.08µV)
SSG MOD: 3.0kHz
2. Open
1) TEST CH: Center, Low, High
Squelch
(3 points)
(5) [Wide]
SSG otuput: –120dBm
(0.22µV)
SSG MOD: 3.0kHz
(5) [Narrow]
2) TEST CH: Center, Low, High
(3 points)
SSG otuput: –119dBm
(0.25µV)
SSG MOD: 1.5kHz
32
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power
ANT
meter
Deviation
meter
Oscilloscope
Measurement
Test-
Unit
Terminal
Unit
equipment
SSG
ANT
DVM
Oscilloscope
Adjustment
Parts
Method
FPU
0.75kHz
±40Hz
0.75kHz
±40Hz
3.0kHz
±100Hz
3.0kHz
±100Hz
Adjustment
Parts
Method
FPU
Press [Start]
(Auto tuning)
Specifications / Remarks
Specifications / Remarks

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-3312 kTk-3312 mTk-3317 mTk-3317Tk-3317 k

Table of Contents