Common Section
Item
Condition
1. Setting
1) BATT terminal votage: 7.5V
2) SSG standard modulation
[Wide]
MOD: 1kHz, DEV: 3kHz
[Narrow]
MOD: 1kHz, DEV: 1.5kHz
2. Receive
1) (Auto tuning)
Assist
*Note
Voltage
2) CH: Low
3. Transmit
1) (Auto tuning)
Assist
*Note
Voltage
2) CH: Low
PTT: ON
Note: At test mode, click [Tune Assist Voltage] button in test mode dialog box, then start automatic adjustment of Recive/Transmit assist voltage.
Transmitter Section
Item
Condition
1. Frequency
1) TEST CH: Center
PTT: ON
2. High
1) TEST CH: Low, Low', Center,
Transmit
High', High (5 points)
Power
BATT terminal voltage: 7.5V
PTT: ON
3. Low
1) TEST CH: Low, Low', Center,
Transmit
High', High (5 points)
Power
BATT terminal voltage: 7.5V
PTT: ON
4. DQT
1) TEST CH: Low, Low', Center,
Balance
High', High (5 points)
[Wide] 1
Deviation meter filter
LPF: 3kHz
HPF: OFF
PTT: ON
5. Maximum
1) TEST CH: Center, Low, Low',
Deviation
High, High' (5 points)
[Wide]
Deviation meter filter
LPF: 15kHz
HPF: OFF
PTT: ON
ADJUSTMENT
Measurement
Test-
Unit
Terminal
equipment
Power
ANT
TX-RX FPU
meter
DVM
TX-RX
CVIN
TX-RX FPU
Measurement
Test-
Unit
Terminal
Unit
equipment
f. counter
ANT
TX-RX FPU
Power
meter
Ammeter
Power
ANT
meter
Deviation
meter
Oscilloscope
TK-3312/3317
Adjustment
Unit
Parts
Method
Check
Check
Adjustment
Parts
Method
485.100MHz
FPU
5.0W
1.0W
Make the demodu-
lation wave into
square waves.
4.4kHz (According
to the larger +, –)
Specifications / Remarks
(4.0V±0.1V)
0.6V or more
(4.0V±0.1V)
0.6V or more
Specifications / Remarks
±50Hz
±0.1W
2.0A or less
±0.1W
1.0A or less
±80Hz
Note:
FPU AUTO INPUT
1kHz/150mV
31