Download Print this page

Kenwood TK-7185 Service Manual Addendum page 21

Vhf fm transceiver 5 tone version
Hide thumbs Also See for TK-7185:

Advertisement

Item
Condition
10. DQT
1) Adj item: [n BAL]
balance
Adjust: [✳✳✳]
adjust
Deviation meter fi lter
LPF: 3kHz
HPF: OFF
• Narrow
2) Adj item: [nL BAL] →
[nC BAL] → [nH BAL]
Adjust: [✳✳✳]
PTT: ON
• Wide
3) Adj item: [w BAL]
Adjust: [✳✳✳]
PTT: ON
11. Max DEV
1) Adj item: [n DEV]
adjust
Adjust: [✳✳✳]
AG: 1kHz/50mV at MIC terminal
Deviation meter fi lter
LPF: 15kHz
HPF: OFF
• Narrow
2) Adj item: [nL DEV] →
[nC DEV] → [nH DEV]
Adjust: [✳✳✳]
PTT: ON
• Wide
3) Adj item: [w DEV]
Adjust: [✳✳✳]
PTT: ON
12. MIC
[Panel test mode]
sensitivity
1) CH-Sig: 1-1
check
AG: 1kHz/5mV at MIC terminal
(Wide only)
PTT: ON
13. QT
1) Adj item: [n QT]
deviation
Adjust: [✳✳✳]
adjust
Deviation meter fi lter
LPF: 3kHz
HPF: OFF
• Narrow
2) Adj item: [nL QT] →
[nC QT] → [nH QT]
Adjust: [✳✳✳]
PTT: ON
• Wide
3) Adj item: [w QT]
Adjust: [✳✳✳]
PTT: ON
14. DQT
1) Adj item: [n DQT]
deviation
Adjust: [✳✳✳]
adjust
Deviation meter fi lter
LPF: 3kHz
HPF: OFF
• Narrow
2) Adj item: [nL DQT] →
[nC DQT] → [nH DQT]
Adjust: [✳✳✳]
PTT: ON
• Wide
3) Adj item: [w DQT]
Adjust: [✳✳✳]
PTT: ON
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power
Rear
ANT
Front
meter
panel
panel
Deviation
Front
Modular
meter
panel
MIC jack
Oscilloscope
AG
AF VTVM
Front
panel
TK-7185
Adjustment
Parts
Method
[ ],[ ] Make the demodu-
lation waves into
square waves.
2.10kHz
±0.05kHz
(According to the
larger +, –)
4.20kHz
±0.10kHz
(According to the
larger +, –)
Check
2.5~3.5kHz
[ ],[ ] 0.35kHz
±0.05kHz
0.75kHz
±0.10kHz
0.35kHz
±0.05kHz
0.75kHz
±0.10kHz
Specifi cations / Remarks