Specifications; Electrical And Refrigerant Data; Kmd-460M_J - Hoshizaki KMD-460MAJ Instruction Manual

Modular crescent cuber
Hide thumbs Also See for KMD-460MAJ:
Table of Contents

Advertisement

I. Specifications
A. Electrical and Refrigerant Data
The rating label and nameplate provide electrical and refrigerant data. The rating label
can be seen by removing the front panel. The nameplate is located on the rear panel. For
certification marks, see the nameplate.
We reserve the right to make changes in specifications and design without prior notice.

1. KMD-460M_J

Model Number
KMD-460MAJ
AC Supply Voltage
115/60/1
Compressor
115V 8.6RLA 54.5LRA
Pump
120V 0.5FLA 23W
Fan
115V 0.5A 63W
Other
115V 0.15A
Maximum Fuse Size 15 AMPS
Max. HACR Breaker
15 AMPS
(USA Only)
Max. Circuit Breaker
15 AMPS
(Canada Only)
Minimum Circuit
15 AMPS
Ampacity
Design Pressure
HI-467PSI LO-230PSI
Refrigerant
404A 1 LB. 5 OZ.
Single Phase
KMD-460MWJ
115/60/1
115V 7.8RLA 54.5LRA
120V 0.5FLA 23W
--- --- ---
115V 0.15A
15 AMPS
15 AMPS
15 AMPS
15 AMPS
HI-427PSI LO-230PSI
404A 14.1 OZ.