Functions
Reach setting
(sensitivity)
The term reach denotes
the approximately circular
diameter that results as the
detection zone.
1 - 8 m
Functions
Twilight setting
(Response threshold)
The desired sensor response
threshold can be adjusted
2
continuously from approx.
LUX
2 lux to 2000 lux.
Adjusting screw right stop
position means: Daylight
operation approx. 2000 lux
(factory setting). Adjusting
screw left stop position
2 - 2000 lux
means: Night-time operation
approx. 2 lux.
Time setting
(Switch-off delay)
The desired duration of il-
lumination of the connected
light can be continuously
adjusted from approx.
30
10 sec. to max. 30 min.
Adjusting screw left stop
position means: shortest
time approx. 10 sec. (fac-
tory setting)
10 sec. - 30 min.
Adjusting screw right stop
position means: longest time
approx. 30 min.
The timer is restarted by any
motion detected before this
time elapses.
(only for HF 360 UP)
Adjusting screw left stop
position means: minimum
reach (approx. 1 m / factory
setting).
Adjusting screw right stop
position means: maximum
reach (approx. 8 m).
(only for IR 180 UP and HF 360 UP)
When adjusting the detec-
tion zone and for the per-
formance test in daylight,
the adjusting screw must be
set to the RH stop position.
The shortest time setting is
recommended when adjus-
ting the detection zone and
performing a functional test.
Note: After every off switch-
ing, further motion detection
is interrupted for approx. 2
seconds. Only after this time
elapses is it possible for the
Sensor Switch to switch
light again.
- 18 -
Button for light functions
Sensor
1 x short
10 sec. - 30 min.
max. 4 hours
Sensor mode
Permanent light mode
The Sensor Switch basically
Button 1 x ON
operates in sensor mode.
The connected light is set
The light is switched ON for
to permanent light for 4
the preset time in response
hours (red LED illuminates).
to movement within the
After this period, the Sensor
detection zone.
Switch immediately returns
to sensor mode (red LED
OFF).
Permanent light can be
interrupted before this time
elapses by pressing the
button (red LED OFF).
(only for IR 180 UP and HF 360 UP)
1 x 3 sec.
OFF
Permanent light OFF mode
Press button for 3 sec.
The connected light is
switched OFF (red LED
fl ashes).
By briefl y pressing the but-
ton again, the Sensor Switch
returns immediately to sen-
sor mode (red LED OFF).
- 19 -