Touch Screen Calibration Function - Icom IC-9700 Basic Manual

Vhf/uhf all mode transceiver
Hide thumbs Also See for IC-9700:
Table of Contents

Advertisement

10
MAINTENANCE

Touch screen calibration function

When no screen action occurs, or a different function
is activated after touching the screen, the touched
point and the detected point may be different.
In that case, the Touch screen calibration function
helps to correct the touch screen sensing accuracy.
1. Open the OTHERS screen.
» SET > Others
MENU
2. Touch "Touch Screen Calibration."
• A dot appears on the screen.
3. Touch the dot that is displayed on the screen.
• A new dot appears in another position.
Touch the displayed dot
4. Repeat step 3.
L When the calibration is complete, the transceiver
returns to the OTHERS screen.
TIP: When the touch screen is not accurate, and
you cannot access the OTHERS screen�
Do the following steps to display the "Touch Screen
Calibration" screen.
1. Turn OFF the transceiver.
2. While holding down
to display the "Touch Screen
POWER
Calibration" screen.
3. Repeat step 3 and 4 on the left column.
4. Touch the frequency readout or a key on the
touch screen to confirm that the touch screen is
working correctly.
10-5
and
, push
MENU
EXIT