Scope of Data to Clear and State of Memory After It Is Cleared
 Safety CPU Unit
Data item
I/O allocation information
Safety programs
Safety password
Event logs
 Safety I/O Units
Data item
FSoE slave address
Event logs
Precautions for Safe Use
After you clear the memory, the Controller operates in the same way as immediately after you
create the system configuration with the Controller in the factory default condition.
Procedure for Clear All Memory Operation
 Clear All Memory Operation for NX Units
1
Go online, right-click a Safety CPU Unit or Safety I/O Unit on the Slave Terminal Tab Page, and
select Clear All Memory from the menu.
You can select this menu command only when the Safety CPU Unit is in PROGRAM mode. The
Clear All Memory for NX Unit Dialog Box is displayed.
2
Click the Execute Button. The Clear All Memory Confirmation Dialog Box is displayed.
3
Click the Yes Button. The Authentication Dialog Box is displayed.
NX-series Safety Control Unit User's Manual (Z930)
8 Checking Operation and Actual Operation
Status after clear all memory operation
This data is set to the default settings (I/O size = 0 bytes).
This data is set to the default settings (no programs).
This data is set to the default settings (no password).
Event logs are cleared if you select the Clear the event logs Option when you
execute the Clear All Memory operation.
Status after clear all memory operation
This data is set to the default setting (no setting).
Event logs are cleared if you select the Clear the event logs Option when you
execute the Clear All Memory operation.
8
8 - 59