Installation - Smeg DO10PSS Instruction Manual

Smeg oven instruction manual
Table of Contents

Advertisement

15. INSTALLATION

15.1 Technical information
Oven type
Electrical connections
Required protection fuse for the oven
OVEN RATING
Ovens
Maximum electrical power
Oven grilling
Large grilling power
Small grilling power
Ovens lightings
OVEN CAVITY DIMENSIONS
Height (cm)
Width (cm)
Depth (cm)
Internal volume (cm
15.2 The rating plate
CHECK THAT MAINS VOLTAGE AND POWER CABLE RATINGS ARE AS PER THE INDICATIONS
PROVIDED ON THE LABEL ATTACHED TO THE OVEN DOOR FRAME.
THIS LABEL MUST NEVER BE REMOVED.
15.3 Electrical connection
IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE GROUNDED ACCORDING TO THE
METHODS REQUIRED BY SAFETY RULES.
WHEN LINKING UP TO MAINS BY PLUG AND SOCKET, MAKE SURE THAT BOTH ARE
COMPATIBLE AND CONNECT BY MEANS OF A POWER CABLE COMPLYING WITH
APPLICABLE REGULATIONS.
THE SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN BUILT IN.
NEVER UNPLUG BY PULLING ON THE CABLE.
IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION TEST OF THE OVEN,
FOLLOWING THE INSTRUCTIONS. SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT
IT FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE.
NEVER ATTEMPT TO REPAIR THE APPLIANCE.
IF A PLUG AND SOCKET CONNECTION IS BEING USED MAKE SURE THAT THE PLUG AND
SOCKET ARE COMPATIBLE. AVOID USE OF ADAPTERS AND SHUNTS AS THESE COULD
CAUSE OVERHEATING AND RISK OF BURNS.
IF A FIXED CONNECTION IS BEING USED FIT POWER LINE WITH AN OMNIPOLAR CIRCUIT
BREAKER WITH A CONTACT OPENING GAP EQUAL TO OR GREATER THAN 3 MM IN AN
EASILY ACCESSIBLE POSITION IN PROXIMITY TO THE OVEN.
50
Instructions for the installer
2
)
Model
See rating plate
230 - 240 / 400-415 V 3N ~ 50 Hz
30 Amps
Electric
6.1 kW
Electric
3.0 kW (230 V)
1.8 kW (230 V)
25 W
(230 V)
Large oven
34
46
40
62560
Serial N°
Small oven
23
46
40
42320

Advertisement

Table of Contents
loading

Table of Contents