Download Print this page

Danfoss PVG 16 Installation Manual

Electrical actuating module pvhc
Hide thumbs Also See for PVG 16:

Advertisement

Quick Links

Installation Guide
PVG 16
Electrical Actuating Module PVHC
Oliestrømmens retning for
standard monterede grupper
Oil flow direction for standard
assembled groups
Richtung des Ölstroms für
Standard-Baugruppen
Sens du débit pour ensembles
standard
Tekniske data
Technical data
Technische Daten
Caractéristiques Techniques
Oil viscosity
Olieviscositet
Range: 12 - 75 mm
Oil viscosity
Ölviskositet
Viscosité de huille
Filtering
Filtering in the
Max. permissible degree of contamination
hydraulic system
(ISO 4406), 1999 version): 23/19/16
Temperature
Ambient
Medium
PVHC er produceret i et miljø, hvor der benyttes mineralsk hydraulikolie
The PVHC is produced in an environment using mineral based hydraulic oil
Das PVHC wird in einer mineralbasierten Hydrauliköl-Umgebung produziert
Le PVHC est fabriqué dans un environnement qui utilise de l'huile hydraulique à base minérale
© Danfoss A/S, 2014-11
Parameter
Controller output
current range
Spool resistance
Pressure control range
/s [65 - 350 SUS]
2
Min.: 4 mm
/s [40 SUS]
2
Max.: 400 mm
/s [2130 SUS]
2
Temperatur range
Min: -30°C to 80°C [-22 to 176°F]
Max: -20°C to 80°C [-4 to 176°F]
L1407359 • Rev AB • Nov 2014
PVHC
PVB
PVP
12 V
0 - 1200 mA
1.0 Ω ± 5%
5 to 15 bar [72.5 to 217.5 psi]
Pilot pressure
Pilottryk (over tanktryk)*
Pilot pressure (over tank)*
Pilotdruck (über Tank)*
Pression pilote (resérvoir)*
*Anvendes sammen med hydraulisk aktiverede glidere
* Designed to be used with hydraulic activated spools
* Entworfen, um mit hydraulisch betriebenen Schieber verwendet zu werden
* Conçu pour une utilisation avec des tiroirs d'activation hydraulique
Max tank pressure
Port T Static
Port T Dynamic
Enclosure
Deutsch DT
P
A
7-9Nm
[61-79 lbf•in]
Q
P
A
max:
Q
P
B
max:
PVM
P301 776
Control range
24 V
0 - 600 mA
0.25 Ω ± 5%
Nom: 25 bar [363 psi]
Min: 21 bar [305 psi]
Max: 25 bar [363 psi]
25 bar [363 psi]
30 bar [435 psi]
Protection class
IP 67
V310175.A
PVS
1

Advertisement

loading

Summary of Contents for Danfoss PVG 16

  • Page 1 The PVHC is produced in an environment using mineral based hydraulic oil Das PVHC wird in einer mineralbasierten Hydrauliköl-Umgebung produziert Le PVHC est fabriqué dans un environnement qui utilise de l’huile hydraulique à base minérale © Danfoss A/S, 2014-11 L1407359 • Rev AB • Nov 2014...
  • Page 2 280/560 mA 500/1000 mA P301 775.A The ideal curve is determined by the main spool neutral spring. The hysteresis is affected by viscosity, friction, flow forces, dither frequency and modulation frequency. L1407359 • Rev AB • Nov 2014 © Danfoss, 2014-11...
  • Page 3 V310 017.A Tilslutning Deutsch version Connection Pos. Description Deutsch code numbers Anschluß Raccordement Housing DT06-2S Lock Part 0462-201-16141 when SOC 16-18 AWG* Pin Contact 0462-209-16141 when SOC 14-16 AWG* V310 004.A L1407359 • Rev AB • Nov 2014 © Danfoss, 2014-11...
  • Page 4 Dimensions for Deutsch version Abmessungen für Deutsch Versionen Encombrements poor Deutsch Version [0.236] [0.236] 39 [1.535] 27 [1.063] 29.4 [1.157] [3.622] [2.913] 18.6 [0.098] [0.732] [0.217] 66.5 [2.618] [1.339] 100.5 [3.957] V310 474.A L1407359 • Rev AB • Nov 2014 © Danfoss, 2014-11...
  • Page 5 L1407359 • Rev AB • Nov 2014 © Danfoss, 2014-11...
  • Page 6 – et du niveau de sécurité – peut étre fait par exemple sur la base de la norme ISO 13849 (parties du systéme de commande relatives á la sécurite). L1407359 • Rev AB • Nov 2014 © Danfoss, 2014-11...