Danfoss PVG 100 Installation Manual
Danfoss PVG 100 Installation Manual

Danfoss PVG 100 Installation Manual

Proportional valve
Hide thumbs Also See for PVG 100:

Advertisement

Installation Guide
Proportional valve
type PVG 100
Installation an plug
orientation
60 Nm
[530 lbf•in]
Modul og
1
PVB
L mm
80.0
128.0
L [in]
[3.15]
[5.04]
© Danfoss A/S, 2015-02
170*
[6.69]
118
[4.65]
100*
[4]
* Room for dismantling
2
3
4
5
176.0
224.0
272.0
[6.93]
[8,82]
[10.71]
11038042 • Rev BC • Feb 2015
L
PVP
A
P
T
B
M12 x 14.0
4 places
6
7
8
320.0
368.0
416.0
[12.60]
[14.49]
[16.38]
170*
[6.69]
100*
[4]
DIN mounting
orientation
60 Nm
[530 lbf•in]
P106 000E
1

Advertisement

Table of Contents
loading

Summary of Contents for Danfoss PVG 100

  • Page 1 Installation Guide Proportional valve type PVG 100 Installation an plug orientation 170* 170* [6.69] [6.69] 60 Nm 60 Nm [530 lbf•in] [530 lbf•in] [4.65] M12 x 14.0 100* 100* 4 places * Room for dismantling P106 000E Modul og L mm 80.0...
  • Page 2 C: PVG code number, week and year of manufacture 3 mm D: PVP pressure setting Q max. B 6 ±1 N•m [53 ±9 lbf•in] Q max. A 10 mm E101 279E 11038042 • Rev BC • Feb 2015 © Danfoss A/S, 2015-02...
  • Page 3: Rated Pressure

    2830 lbf·in Rated pressure Product Rated pressure PVG 100 350 bar [5076 psi] PVG 100 w. HIC steel 350 bar [5076 psi] PVG 100 w. HIC aluminium 210 bar [3046 psi] PVG 100/32 w. PVBZ 210 bar [3046 psi] PVG 100/32 w. PVS 300 bar [4351 psi] PVG 100/32 w.
  • Page 4: Installation Of Lever

    Installation of lever Base with an angle of 22.5° Base with an angle of 37.5° P106 007E Pressure setting PVP-CC PVP-OC 360° ~ 120 bar 360° ~ 1740 psi P106 008E 11038042 • Rev BC • Feb 2015 © Danfoss A/S, 2015-02...
  • Page 5 Direction of rotation for adjustment of position transducer PVG 100 Direction A Direction B Turn of transducer Movement of lever 1.5 mm [0.06 in] 3.0 mm [0.12 in] 4.5 mm [0.18 in] © Danfoss A/S, 2015-02 11038042 • Rev BC • Feb 2015...
  • Page 6 110°C (230°F) coil temperature 12 W 12 W Max. permissible deviation from rated supply voltage ±10% When installing the wire remember to connect the built-in diode to the plug pins. P106 004E 11038042 • Rev BC • Feb 2015 © Danfoss A/S, 2015-02...
  • Page 7 110°C (230°F) coil temperature 12 W 12 W Max. permissible deviation from rated supply voltage ±10% When installing the wire remember to connect the built-in diode to the plug pins. P106 288E © Danfoss A/S, 2015-02 11038042 • Rev BC • Feb 2015...
  • Page 8: Pvmr Disassembly

    PVMR Disassembly P106 005 11038042 • Rev BC • Feb 2015 © Danfoss A/S, 2015-02...
  • Page 9: Pvmr/F Assembly

    Width across flats 8 ± 0.5 Nm 15 ± 2 Nm 4 ± 1 Nm Tightening torque [70 ± 4.5 lbf·in] [135 ± 20 lbf·in] [35 ± 9 lbf·in] P106 006 © Danfoss A/S, 2015-02 11038042 • Rev BC • Feb 2015...
  • Page 10: Standard Main Spool Assembly

    Standard main spool assembly for PVMR 12.5 mm 8 Nm 8 Nm [70 lbf·in] [70 lbf·in] E101 291E 11038042 • Rev BC • Feb 2015 © Danfoss A/S, 2015-02...
  • Page 11 Standard float spool assembly for PVMR 8 Nm [70 lbf·in] Not: Spools must be installed with LS 8 Nm holes on 'B' port side of PVB [70 lbf·in] E101 290E © Danfoss A/S, 2015-02 11038042 • Rev BC • Feb 2015...
  • Page 12 11038042 • Rev BC • Feb 2015 © Danfoss A/S, 2015-02...

Table of Contents