Instructions for the Installer
4.1

Bottled gas connection

Use a pressure regulator and make the connection to the gas cylinder in accordance
with the relevant regulations. Make sure that the gas supply pressure is as stated in
the table in point "5.2 Adjusting for bottled gas".
4.2

Room ventilation

The appliance may only be installed in a permanently ventilated room as specified by
the relevant regulations. The air flow into the room where the appliance is installed
must be sufficient for proper gas combustion and room ventilation. The air intakes,
protected by gratings, must be of suitable size (see relevant regulations) and located
so that they cannot be even partially obstructed.
The kitchen must be kept properly ventilated to disperse the heat and humidity
produced by cooking processes: in particular, a window should be opened or the
speed of any fans increased after prolonged use.
4.3

Combustion gas discharge

Combustion gases may be discharged by means of hoods connected to a flue with
reliable natural draught, or a fan extraction system. An effective extraction system
requires careful design by an authorised specialist, and must comply with the
regulation distances and positions. After installation, the engineer must issue a
certificate of compliance.