Daikin 2MXS-N Series Engineering Data page 81

Multi-split type air conditioners, r410a, inverter
Hide thumbs Also See for 2MXS-N Series:
Table of Contents

Advertisement

Dimensions
CDXS15/18LVJU
35-7/16 (900mm)
(ALL AROUND)
22-φ 3/16 (φ 4.7mm) HOLES
8
8xP.3-15/16 (100mm)=31-1/2 (800mm)
37 (940mm)
(SUSPENSION BOLT PITCH)
34-5/8 (880mm)
33-7/8 (860mm)
3-9/16 (90mm)
4xP.5-7/8 (150mm)=23-5/8 (600mm)
18-M4 HOLES
(ALL AROUND)
7xP.3-15/16 (100mm)=27-9/16 (700mm)
30-11/16 (780mm)
31-1/2 (800mm)
9
32-5/16 (820mm)
< IN CASE OF BOTTOM-SUCTION >
CDXS24LVJU
( ALL AROUND )
26-φ3/16 HOLE
8
10× ( P3-15/16 ) =39-3/8
( SUSPENSION BOLT PITCH )
SUSPENSION BOLT
4-M8~M10
6×P5-7/8=35-7/16
18-M4 HOLES
( ALL AROUND )
9× ( P3-15/16 ) =35-7/16
9
IN CASE OF BOTTOM-SUCTION
76
11-13/16 (300mm) OR MORE
(SERVICE SPACE)
< SERVICE SPACE >
5-1/8 (130mm)
3-9/16 (90mm)
SUSPENSION BOLT
4-UNC5/16 ~ 3/8
(M8 ~ M10)
1-3/16 (30mm)
4
20-M5 HOLES
(ALL AROUND)
NOTE)
1. IN CASE OF BACK-SUCTION,
10
6
2. LOCATION OF UNIT'S NAME PLATE: CONTROL BOX COVER
5-1/8 (130mm)
3. MOUNT THE AIR FILTER AT THE SUCTION SIDE.
3-15/16 (100mm)
(
3-9/16 (90mm)
3-1/8 (80mm)
43-5/16
11-13/16 OR MORE
( SERVICE SPACE )
44-7/8
42-1/2
41-3/4
1-3/16
4
24-M5 HOLES
( ALL AROUND )
NOTE )1. IN CASE OF BACK-SUCTION , MOUNT CHAMBER COVER
10
6
5-1/8
38-9/16
3-15/16
39-3/8
3-9/16
40-3/16
3-1/8
24-7/16 (620mm)
15-3/4 (400mm) OR MORE
(IN CASE OF
BOTTOM SUCTION)
CEILING
2-1/2 (63mm)
ARROW VIEW
INSPECTION DOOR
(CEILING OPENING)
2
1
20-M5 HOLES
(ALL AROUND)
13 (330mm)
5-7/8 (150 mm)
3
5
3-15/16 (100 mm)
3-9/16 (90mm)
3-1/8 (80mm)
MOUNT CHAMBER COVER TO BOTTOM SIDE OF THE UNIT.
IN CASE OF BOTTOM-SUCTION,
MOUNT CHAMBER COVER TO BACK SIDE OF THE UNIT.
)
SELECT ITS COLORIMETHOD (GRAVITY METHOD)
50% OR MORE.
IT CAN NOT BE EQUIPPED WITH AIR FILTER (ACCESSORY)
WHEN CONNECTING DUCT TO SUCTION SIDE.
24-7/16
15-3/4 OR MORE
( IN CASE OF
BOTTOM SUCTION )
CEILING
SERVICE SPACE
ARROW VIEW
INSPECTION DOOR
( CEILING OPENING )
2
1
5-1/8
2-1/2
24-M5 HOLES
( ALL AROUND )
13
5-7/8
3
3-15/16
5
3-9/16
3-1/8
TO BOTTOM SIDE OF THE UNIT.
IN CASE OF BOTTOM-SUCTION , MOUNT CHAMBER COVER
TO BACK SIDE OF THE UNIT.
2. LOCATION OF UNIT'S NAME PLATE: CONTROL BOX COVER
3. MOUNT THE AIR FILTER AT THE SUCTION SIDE.
(
SELECT ITS COLORIMETHOD ( GRAVITY METHOD )
50% OR MORE.
IT CAN NOT BE EQUIPPED WITH AIR FILTER ( ACCESSORY )
WHEN CONNECTING DUCT TO SUCTION SIDE.
Multi-Split Type Air Conditioners 2/3/4MXS-N Series
(1-3/4) (45mm)
11/16 (18mm)
2-5/16 (58mm)
ROOM TEMP.
2-3/4
(13/16)
1-1/2 (38mm)
SENSOR
(20mm)
(70mm)
OPERATION LAMP
TIMER LAMP
INDOOR UNIT
ON/OFF SWITCH
SIGNAL RECEIVER
CORD (LENGTH: 74-13/16)
( :1900mm)
INFRARED RECEIVER UNIT
WIRELESS REMOTE CONTROLLER
10
7
7xP.3-15/16 (100)=27-9/16 (700mm)
30-11/16 (780mm)
31-1/2 (800mm)
32-5/16 (820mm)
<IN CASE OF BACK-SUCTION>
10
PROTECTION NET
9
AIR FILTER (ACCESSORY)
8
SUSPENSION BRACKET
7
POWER SUPPLY CONNECTION
6
INFRARED RECEIVER UNIT CONNECTION
5
CONTROL BOX
4
DRAIN HOSE (ACCESSORY)
I.D.φ 31/32 (φ 25mm) (OUTLET)
3
SOCKET FOR DRAIN
VP20 O.D.φ 1-1/32 (φ 26mm)
(
/I.D.φ 25/32 (φ 20mm)
GAS PIPE CONNECTION φ 1/2 (φ 12.7mm) (FLARE CONNECTION)
2
φ 1/4 (φ 6.4mm) (FLARE CONNECTION)
1
LIQUID PIPE CONNECTION
NAME
DESCRIPTION
NUMBER
( 1-3/4 )
ROOM TEMP.
( 13/16 )
2-3/4
1-1/2
SENSOR
OPERATION LAMP
TIMER LAMP
INDOOR UNIT
ON/OFF SWITCH
SIGNAL RECEIVER
CORD ( LENGTH: 74-13/16 )
INFRARED RECEIVER UNIT WIRELESS REMOTE CONTROLLER
7
9× ( P3-15/16 ) =35-7/16
38-9/16
39-3/8
40-3/16
IN CASE OF BACK-SUCTION
10
PROTECTION NET
AIR FILTER ( STANDARD ACCESSORY )
9
8
SUSPENSION BRACKET
7
POWER SUPPLY CONNECTION
6
INFRARED RECEIVER UNIT CONNECTION
5
CONTROL BOX
I.D. φ31/32 ( OUTLET )
DRAIN HOSE ( STANDARD ACCESSORY )
4
VP20 ( O.D. φ1-1/32/I.D. φ25/32 )
3
SOCKET FOR DRAIN
φ5/8 ( FLARE CONNECTION )
)
2
GAS PIPE CONNECTION
φ1/4 ( FLARE CONNECTION )
1
LIQUID PIPE CONNECTION
NUMBER
NAME
EDUS121503A
SIGNAL TRANSMITTER
(ARC452A23)
9
)
3D075268
SIGNAL
TRANSMITTER
11/16
2-5/16
(ARC452A23)
10
9
DESCRIPTION
3D080591