Daikin 2MXS-N Series Engineering Data page 100

Multi-split type air conditioners, r410a, inverter
Hide thumbs Also See for 2MXS-N Series:
Table of Contents

Advertisement

EDUS121503A
Outdoor air
Combination
temp.
(Capacity)
EDB (°F)
CTXS07L +
68.0
FDXS12L
77.0
86.0
89.6
95.0
104.0
109.4
114.8
CTXS07L +
68.0
FTXS15L
77.0
86.0
89.6
95.0
104.0
109.4
114.8
CTXS07L +
68.0
CDXS15L
77.0
86.0
89.6
95.0
104.0
109.4
114.8
FTXS09L +
68.0
FTXS09L
77.0
86.0
89.6
95.0
104.0
109.4
114.8
FTXS09L +
68.0
FDXS09L
77.0
86.0
89.6
95.0
104.0
109.4
114.8
FDXS09L +
68.0
FDXS09L
77.0
86.0
89.6
95.0
104.0
109.4
114.8
Multi-Split Type Air Conditioners 2/3/4MXS-N Series
57.2
60.8
TC
PI
TC
PI
kBtu/h
kW
kBtu/h
kW
20.08
1.45
20.98
1.48
19.17
1.54
20.07
1.57
18.26
1.64
19.16
1.67
17.89
1.68
18.79
1.71
17.34
1.74
18.25
1.77
16.43
1.85
17.33
1.88
15.19
1.77
15.90
1.77
9.61
0.98
10.00
0.98
21.51
1.23
22.48
1.25
20.54
1.30
21.50
1.33
19.56
1.38
20.53
1.41
19.17
1.42
20.14
1.44
18.58
1.47
19.55
1.49
17.60
1.56
18.57
1.59
17.02
1.62
17.98
1.65
11.01
0.98
11.48
0.98
20.08
1.36
20.98
1.38
19.17
1.44
20.07
1.47
18.26
1.53
19.16
1.55
17.89
1.57
18.79
1.59
17.34
1.62
18.25
1.65
16.43
1.73
17.33
1.76
15.77
1.77
16.52
1.77
9.88
0.98
10.29
0.98
21.51
1.55
22.48
1.58
20.54
1.64
21.50
1.67
19.56
1.74
20.53
1.78
19.17
1.79
20.14
1.82
18.58
1.85
19.55
1.89
17.60
1.97
18.57
2.00
15.72
1.77
16.44
1.77
9.91
0.98
10.30
0.98
20.08
1.44
20.98
1.47
19.17
1.52
20.07
1.55
18.26
1.62
19.16
1.65
17.89
1.66
18.79
1.69
17.34
1.72
18.25
1.75
16.43
1.83
17.33
1.86
15.28
1.77
15.99
1.77
9.65
0.98
10.04
0.98
18.54
1.30
19.38
1.33
17.70
1.38
18.53
1.41
16.86
1.46
17.69
1.49
16.52
1.50
17.35
1.53
16.02
1.56
16.85
1.58
15.17
1.66
16.01
1.68
14.67
1.72
15.50
1.75
9.43
0.98
9.82
0.98
Indoor air temp. EWB (°F)
64.4
67.0
TC
PI
TC
PI
kBtu/h
kW
kBtu/h
kW
21.89
1.51
22.34
1.53
20.97
1.60
21.43
1.61
20.06
1.69
20.51
1.71
19.70
1.73
20.15
1.75
19.15
1.80
19.60
1.81
18.24
1.91
18.69
1.92
16.59
1.77
16.93
1.77
10.38
0.98
10.56
0.98
23.45
1.28
23.93
1.29
22.47
1.35
22.96
1.36
21.49
1.43
21.98
1.44
21.10
1.47
21.59
1.48
20.52
1.52
21.00
1.53
19.54
1.61
20.02
1.63
18.95
1.67
19.44
1.69
11.94
0.98
12.16
0.98
21.89
1.41
22.34
1.42
20.97
1.49
21.43
1.51
20.06
1.58
20.51
1.60
19.70
1.62
20.15
1.63
19.15
1.68
19.60
1.69
18.24
1.78
18.69
1.80
17.24
1.77
17.60
1.77
10.69
0.98
10.88
0.98
23.45
1.61
23.93
1.63
22.47
1.70
22.96
1.72
21.49
1.81
21.98
1.82
21.10
1.85
21.59
1.86
20.52
1.92
21.00
1.93
19.54
2.04
20.02
2.05
17.14
1.77
17.49
1.77
10.69
0.98
10.88
0.98
21.89
1.49
22.34
1.51
20.97
1.58
21.43
1.60
20.06
1.68
20.51
1.69
19.70
1.72
20.15
1.73
19.15
1.78
19.60
1.79
18.24
1.89
18.69
1.90
16.69
1.77
17.03
1.77
10.42
0.98
10.61
0.98
20.21
1.35
20.63
1.37
19.37
1.43
19.79
1.44
18.53
1.52
18.94
1.53
18.19
1.55
18.61
1.57
17.68
1.61
18.10
1.62
16.84
1.71
17.26
1.72
16.33
1.77
16.68
1.77
10.20
0.98
10.39
0.98
Capacity Tables
71.6
75.2
TC
PI
TC
PI
kBtu/h
kW
kBtu/h
kW
23.69
1.57
24.60
1.60
22.78
1.66
23.68
1.69
21.87
1.75
22.77
1.78
21.50
1.79
22.41
1.82
20.95
1.86
21.86
1.88
20.04
1.97
20.94
2.00
17.92
1.77
18.56
1.77
11.11
0.98
11.46
0.98
25.38
1.33
26.35
1.35
24.41
1.40
25.37
1.42
23.43
1.48
24.40
1.51
23.04
1.52
24.01
1.54
22.45
1.57
23.42
1.59
21.47
1.66
22.44
1.69
20.89
1.72
21.85
1.75
12.82
0.98
13.24
0.98
23.69
1.47
24.60
1.49
22.78
1.55
23.68
1.57
21.87
1.64
22.77
1.66
21.50
1.67
22.41
1.70
20.95
1.73
21.86
1.76
20.04
1.84
20.94
1.86
18.64
1.77
19.31
1.77
11.46
0.98
11.83
0.98
25.38
1.67
26.35
1.70
24.41
1.77
25.37
1.80
23.43
1.87
24.40
1.90
23.04
1.91
24.01
1.94
22.45
1.98
23.42
2.01
21.47
2.10
22.44
2.13
18.49
1.77
19.15
1.77
11.43
0.98
11.79
0.98
23.69
1.55
24.60
1.58
22.78
1.64
23.68
1.67
21.87
1.73
22.77
1.76
21.50
1.77
22.41
1.80
20.95
1.83
21.86
1.86
20.04
1.94
20.94
1.97
18.03
1.77
18.68
1.77
11.16
0.98
11.52
0.98
21.88
1.40
22.71
1.43
21.04
1.48
21.87
1.51
20.19
1.57
21.03
1.59
19.86
1.60
20.69
1.63
19.35
1.66
20.18
1.69
18.51
1.76
19.34
1.79
17.69
1.77
18.33
1.77
10.94
0.98
11.30
0.98
95
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents